Background Fracture of nickel-titanium (Ni-Ti) instruments in root canals is commonly associated with compromised outcomes in endodontic treatment. There is no single, universally accepted approach for managing this complication. The objective of this study is to evaluate the effectiveness of an Nd: YAP laser-assisted protocol in removing fractured Ni-Ti files in teeth with minimal root curvature (less than 15 degrees). Methods A total of 66 notched Ni-Ti files located at the apical third of the extracted teeth with minimal root curvature (less than 15 degrees) were included. The Nd: YAP laser was used with parameters set to a power of 3W, delivering 300 mJ per pulse. The fiber had a diameter of 200 µm, and the laser operated in pulsed mode at a frequency of 10 Hz, a pulse duration of 150 𝜇s, and an energy density of 955.41 J/cm per second. The safety of the irradiation parameters was proven in a previous study. The edge of the laser fiber was inserted in the canal until close contact with the fractured file was achieved during all the irradiation procedures. Total elimination and bypass of the instrument were considered a success while partial bypass, non-bypass, or lateral perforation were considered a failure. In addition, the average time required to bypass or eliminate the broken Ni-Ti files was recorded. Scanning electron microscopy (SEM) was used to evaluate physical modifications after irradiation, and X-ray emission spectroscopy was employed to calculate the percentage of nickel and titanium incorporated into the dentinal walls of the canals. Results Six samples were excluded from the study. From the 60 included, the success rate was 100%, with 71.66% (n=43) bypass and 28.33% total elimination (n=17) of the fractured instrument. The mean and standard deviation of the measured time for bypassing or completely removing the broken files was 7.463 ± 3.679 seconds. Chemical analysis revealed that Ni and Ti residues were predominantly present in the irradiated canal area with a mass percentage of 5.548 ± 4.621 and 7.371% ± 5.393 for Ni and Ti, respectively, at the impact area and decreased toward the apical region. Conclusion This study proposes a promising protocol using Nd: YAP laser for removing fractured Ni-Ti files in teeth with minimal root curvature that is less than 15 degrees.

摘要

背景 根管内镍钛(Ni-Ti)器械折断通常与牙髓治疗效果不佳相关。目前尚无一种被普遍接受的处理该并发症的方法。本研究的目的是评估钕钇铝石榴石(Nd:YAP)激光辅助方案在去除牙根弯曲度最小(小于15度)的牙齿中折断的Ni-Ti锉的有效性。方法 共纳入66个位于牙根弯曲度最小(小于15度)的离体牙根尖三分之一处的带缺口Ni-Ti锉。使用Nd:YAP激光,参数设置为功率3W,每脉冲输出300mJ。光纤直径为200μm,激光以脉冲模式运行,频率为10Hz,脉冲持续时间为150μs,能量密度为955.41J/cm²每秒。先前的一项研究已证明了照射参数的安全性。在所有照射过程中,将激光光纤的边缘插入根管,直至与折断的锉紧密接触。器械的完全去除和绕过被视为成功,而部分绕过、未绕过或侧穿则被视为失败。此外,记录绕过或去除折断的Ni-Ti锉所需的平均时间。使用扫描电子显微镜(SEM)评估照射后的物理变化,并采用X射线发射光谱法计算镍和钛掺入根管牙本质壁的百分比。结果 6个样本被排除在研究之外。在纳入的60个样本中,成功率为100%,其中71.66%(n = 43)的折断器械被绕过,28.33%(n = 17)被完全去除。绕过或完全去除折断锉的测量时间的平均值和标准差为7.463±3.679秒。化学分析表明,镍和钛残留物主要存在于照射后的根管区域,在撞击区域,镍和钛的质量百分比分别为5.548±4.621和7.371%±5.393,向根尖区域减少。结论 本研究提出了一种有前景的方案,即使用Nd:YAP激光去除牙根弯曲度小于15度的牙齿中折断的Ni-Ti锉。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7443/11702891/f4aaf5457422/cureus-0016-00000075276-i01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验