Palamarchuk Iryna, Ives Colleen T, Hachinski Vladimir, Kimpinski Kurt
Department of Clinical Neurological Sciences, University Hospital, London Health Sciences Centre, London, Ontario, Canada; Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada.
Department of Clinical Neurological Sciences, University Hospital, London Health Sciences Centre, London, Ontario, Canada.
Auton Neurosci. 2014 Oct;185:138-40. doi: 10.1016/j.autneu.2014.05.002. Epub 2014 May 14.
The reliability of the baroreflex sensitivity measurement has not yet been established. Thus, the objective of this study was to define intra-rater reliability of baroreflex sensitivity (BRS) measurements of the Valsalva maneuver (VM) in healthy individuals. Twenty-two healthy volunteers underwent VM testing at two time points. Intra-rater reliability was determined by the intra-class correlation coefficient (ICC), standard error of measurement and minimal detectable difference. Vagal BRS showed good reliability (ICC=0.84), while alternative adrenergic BRS was moderately reproducible (ICC=0.61). Vagal and alternative adrenergic components of BRS in VM are reliable measurements.