Suppr超能文献

基于Scheimpflug动态眼压测量法评估准分子激光原位角膜磨镶术(LASIK)、角膜基质透镜切除术(ReLEx flex)和全飞秒激光微小切口基质透镜切除术(ReLEx smile)后的角膜生物力学特性

Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry.

作者信息

Pedersen Iben Bach, Bak-Nielsen Sashia, Vestergaard Anders Højslet, Ivarsen Anders, Hjortdal Jesper

机构信息

Department of Ophthalmology, Aarhus University Hospital, Nørrebrogade 44, 8000, Aarhus C, Denmark,

出版信息

Graefes Arch Clin Exp Ophthalmol. 2014 Aug;252(8):1329-35. doi: 10.1007/s00417-014-2667-6. Epub 2014 May 27.

Abstract

PURPOSE

To evaluate corneal biomechanical properties after LASIK, ReLEx flex, and the flap-free procedure ReLEx smile by Scheimpflug-based dynamic tonometry (Corvis ST) and non-contact differential tonometry (Ocular Response Analyzer, ORA).

METHODS

Patients treated for high myopia (-10.5 to -5.5 diopters, spherical equivalent refraction) more than one year previously at Aarhus University Hospital were included. Treatments comprised LASIK (35 eyes), ReLEx flex (31 eyes), and ReLEx smile (29 eyes). A control group included 31 healthy eyes. Cornea-compensated IOP (IOPcc), corneal hysteresis (CH), and corneal resistance factor (CRF) were measured with ORA. Corneal applanation and deformation were registered with Corvis ST during an air-pulse.

RESULTS

Multiple linear regression analysis showed that CH and CRF were significantly lower after all keratorefractive procedures compared to healthy controls (p < 0.05). No significant differences were observed in CH or CRF between the keratorefractive groups. Corvis ST showed no differences in radius at highest concavity (HC radius), time until first applanation (A1 Time), time until second applanation (A2 Time), and deflection length at highest concavity (HC deflection length) between groups. LASIK treated eyes had significantly shorter time until highest concavity than eyes treated with ReLEx smile (HC Time, p = 0.01). The A1 deflection length was significantly shorter in the keratorefractive groups compared to the healthy controls (p < 0.05).

CONCLUSIONS

Keratorefrative procedures alter the corneal biomechanical properties with regard to corneal hysteresis and corneal resistant factor. The flap-based LASIK and ReLEx flex and the flap-free ReLEx smile result in similar reduction in corneal biomechanics when evaluated by Corvis ST and ORA.

摘要

目的

通过基于Scheimpflug原理的动态眼压测量法(Corvis ST)和非接触式差分眼压测量法(眼反应分析仪,ORA)评估准分子激光原位角膜磨镶术(LASIK)、ReLEx flex以及无瓣手术ReLEx smile术后的角膜生物力学特性。

方法

纳入一年多以前在奥胡斯大学医院接受高度近视(-10.5至-5.5屈光度,等效球镜度)治疗的患者。治疗方式包括LASIK(35只眼)、ReLEx flex(31只眼)和ReLEx smile(29只眼)。对照组包括31只健康眼。使用ORA测量角膜补偿眼压(IOPcc)、角膜滞后(CH)和角膜阻力因子(CRF)。在空气脉冲期间,用Corvis ST记录角膜压平及变形情况。

结果

多元线性回归分析显示,与健康对照组相比,所有角膜屈光手术术后的CH和CRF均显著降低(p < 0.05)。角膜屈光手术组之间在CH或CRF方面未观察到显著差异。Corvis ST显示,各组之间在最大凹陷处半径(HC半径)、首次压平时间(A1时间)、第二次压平时间(A2时间)以及最大凹陷处偏转长度(HC偏转长度)方面无差异。LASIK治疗的眼睛达到最大凹陷的时间明显短于接受ReLEx smile治疗的眼睛(HC时间,p = 0.01)。与健康对照组相比,角膜屈光手术组的A1偏转长度明显更短(p < 0.05)。

结论

角膜屈光手术在角膜滞后和角膜阻力因子方面改变了角膜生物力学特性。当通过Corvis ST和ORA评估时,基于瓣的LASIK和ReLEx flex以及无瓣的ReLEx smile在角膜生物力学方面导致相似程度的降低。