Suppr超能文献

闭角型青光眼在暗室和明室条件下前房角的评估:一项眼前节光学相干断层扫描研究

Evaluation of anterior chamber angle under dark and light conditions in angle closure glaucoma: An anterior segment OCT study.

作者信息

Masoodi Habibeh, Jafarzadehpur Ebrahim, Esmaeili Alireza, Abolbashari Fereshteh, Ahmadi Hosseini Seyed Mahdi

机构信息

Optometry Department, International Branch of Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Optometry Department, Iran University of Medical Sciences, Tehran, Iran.

出版信息

Cont Lens Anterior Eye. 2014 Aug;37(4):300-4. doi: 10.1016/j.clae.2014.04.002. Epub 2014 Jun 6.

Abstract

AIM

To evaluate changes of nasal and temporal anterior chamber angle (ACA) in subjects with angle closure glaucoma using Spectralis AS-OCT (SAS-OCT) under dark and light conditions.

METHODS

Based on dark-room gonioscopy, 24 subjects with open angles and 86 with narrow angles participated in this study. The nasal and temporal angle opening distance at 500 μm anterior to the scleral spur (AOD500), nasal and temporal ACA were measured using SAS-OCT in light and dark conditions.

RESULT

In 2 groups, ACA and AOD500 in nasal and temporal quadrants were significantly greater in light compared to dark (all with p=0.000). The AOD500 and ACA were significantly higher in nasal than temporal in measured conditions for 2 groups except the ACA and AOD500 of normal group measured in light. The difference between nasal and temporal in dark (29.07 ± 65.71 μm for AOD500 and 5.7 ± 4.07° for ACA) was greater than light (24.86 ± 79.85 μm for AOD500 and 2.09 ± 7.21° for ACA) condition. But the difference was only significant for ACA (p=0.000). The correlation analysis showed a negative correlation between AOD500 and pupil diameter in temporal and nasal quadrants (both with p=0.000). While temporal AOD500 difference correlated with spherical equivalent, temporal and asal gonioscopy, nasal AOD correlated with IOP, temporal and nasal gonioscopy.

CONCLUSIONS

Clinically important changes in ACA structure could be detected with SAS-OCT in nasal and temporal quadrants under different illumination intensity. The results could help in improvement of examination condition for better and more accurate assessment of individuals with angle closure glaucoma.

摘要

目的

使用Spectralis AS-OCT(SAS-OCT)评估在暗室和明室条件下角闭青光眼患者鼻侧和颞侧前房角(ACA)的变化。

方法

基于暗室房角镜检查,24例房角开放患者和86例房角狭窄患者参与了本研究。使用SAS-OCT在明室和暗室条件下测量巩膜突前500μm处的鼻侧和颞侧房角开放距离(AOD500)、鼻侧和颞侧ACA。

结果

在两组中,与暗室相比,明室条件下鼻侧和颞侧象限的ACA和AOD500均显著更大(均p = 0.000)。除正常组明室测量的ACA和AOD500外,两组在测量条件下鼻侧的AOD500和ACA均显著高于颞侧。暗室条件下鼻侧和颞侧的差异(AOD500为29.07±65.71μm,ACA为5.7±4.07°)大于明室条件(AOD500为24.86±79.85μm,ACA为2.09±7.21°)。但仅ACA差异具有统计学意义(p = 0.000)。相关性分析显示,颞侧和鼻侧象限的AOD500与瞳孔直径呈负相关(均p = 0.000)。而颞侧AOD500差异与球镜等效度、颞侧和鼻侧房角镜检查相关,鼻侧AOD与眼压、颞侧和鼻侧房角镜检查相关。

结论

使用SAS-OCT可在不同光照强度下检测鼻侧和颞侧象限ACA结构的临床重要变化。这些结果有助于改善检查条件,以便更好、更准确地评估角闭青光眼患者。