Suppr超能文献

利用单次尿样估算 24 小时尿钠排泄量。

Estimation of 24-hour urinary sodium excretion using spot urine samples.

机构信息

Cardiovascular Center, Dongguk University Ilsan Hospital, 27 Dongguk-ro, Ilsandong-gu, Goyang-si, Gyeonggi 410-773, Korea.

Division of Nephrology, Dongguk University Ilsan Hospital, 27 Dongguk-ro, Ilsandong-gu, Goyang-si, Gyeonggi 410-773, Korea.

出版信息

Nutrients. 2014 Jun 20;6(6):2360-75. doi: 10.3390/nu6062360.

Abstract

The present study evaluated the reliability of equations using spot urine (SU) samples in the estimation of 24-hour urine sodium excretion (24-HUNa). Equations estimating 24-HUNa from SU samples were derived from first-morning SU of 101 participants (52.4 ± 11.1 years, range 24-70 years). Equations developed by us and other investigators were validated with SU samples from a separate group of participants (n = 224, 51.0 ± 10.9 years, range 24-70 years). Linear, quadratic, and cubic equations were derived from first-morning SU samples because these samples had a sodium/creatinine ratio having the highest correlation coefficient for 24-HUNa/creatinine ratio (r = 0.728, p < 0.001). In the validation group, the estimated 24-HUNa showed significant correlations with measured 24-HUNa values. The estimated 24-HUNa by the linear, quadratic, and cubic equations developed from our study were not significantly different from measured 24-HUNa, while estimated 24-HUNa by previously developed equations were significantly different from measured 24-HUNa values. The limits of agreement between measured and estimated 24-HUNa by six equations exceeded 100 mmol/24-hour in the Bland-Altman analysis. All equations showed a tendency of under- or over-estimation of 24-HUNa, depending on the level of measured 24-HUNa. Estimation of 24-HUNa from single SU by equations as tested in the present study was found to be inadequate for the estimation of an individual's 24-HUNa.

摘要

本研究评估了使用单次尿样(SU)估算 24 小时尿钠排泄量(24-HUNa)的方程的可靠性。从 101 名参与者(52.4±11.1 岁,年龄范围 24-70 岁)的首次晨尿 SU 中推导出估算 24-HUNa 的方程。我们和其他研究人员开发的方程通过来自另一组参与者的 SU 样本进行验证(n=224,51.0±10.9 岁,年龄范围 24-70 岁)。从首次晨尿 SU 中推导出线性、二次和三次方程,因为这些样本的钠/肌酐比值与 24-HUNa/肌酐比值的相关性最高(r=0.728,p<0.001)。在验证组中,估算的 24-HUNa 与测量的 24-HUNa 值呈显著相关性。由本研究开发的线性、二次和三次方程估算的 24-HUNa 与测量的 24-HUNa 值无显著差异,而之前开发的方程估算的 24-HUNa 与测量的 24-HUNa 值有显著差异。在 Bland-Altman 分析中,六种方程中测量值和估算值之间的 24-HUNa 一致性界限在 100mmol/24 小时以上。所有方程都显示出根据测量的 24-HUNa 值,估算的 24-HUNa 存在低估或高估的趋势。在本研究中测试的单次 SU 方程估算 24-HUNa 的结果表明,不足以估计个体的 24-HUNa。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1e02/4073156/d5d16476ae7f/nutrients-06-02360-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验