Curiale M S, Fahey P, Fox T L, McAllister J S
Silliker Laboratories, Inc., Chicago Heights, IL 60411.
J Assoc Off Anal Chem. 1989 Mar-Apr;72(2):312-8.
A collaborative study was conducted to compare proposed dry-film plating methods, using aerobic count plates and coliform count plates, to standard agar plating methods for quantifying aerobic bacteria and coliforms in dairy products. In this study, 5 food products (chocolate milk, pasteurized cheese, nonfat dry milk, evaporated milk, and vanilla ice cream), selected as representative dairy products, were analyzed by 11 collaborating laboratories. The results indicate that the dry-film plating methods are equivalent to or better than the agar plating methods. The aerobic count and coliform count dry-film plating methods have been adopted official first action.
开展了一项合作研究,以比较使用需氧菌计数平板和大肠菌群计数平板的拟议干膜平板法与用于定量乳制品中需氧菌和大肠菌群的标准琼脂平板法。在本研究中,11个合作实验室对选定为代表性乳制品的5种食品(巧克力牛奶、巴氏杀菌奶酪、脱脂奶粉、炼乳和香草冰淇淋)进行了分析。结果表明,干膜平板法等同于或优于琼脂平板法。需氧菌计数和大肠菌群计数干膜平板法已被正式首次采用。