Suppr超能文献

磁共振成像伪影与固定正畸附件

Magnetic resonance imaging artefacts and fixed orthodontic attachments.

作者信息

Beau Aurélien, Bossard Denis, Gebeile-Chauty Sarah

机构信息

*Faculty of Odontology, Lyon,

**Center for Medical Imaging Mermoz, Lyon, and.

出版信息

Eur J Orthod. 2015 Feb;37(1):105-10. doi: 10.1093/ejo/cju020. Epub 2014 Jul 4.

Abstract

BACKGROUND/OBJECTIVES: Orthodontic appliances are often removed before magnetic resonance imaging (MRI) scans because they are known to produce artefacts. The purpose of this study was to find the exact indications for removal of various fixed attachments when imaging four specific areas of the head and neck.

MATERIALS/METHODS: Sixty patients requiring an MRI scan of the head for medical reasons volunteered for this investigation. One of four different types of fixed attachments (stainless steel brackets, titanium brackets, ceramic brackets with metal slots, and stainless steel retainers) were assigned to a patient. Each patient had two scans at 1.5 T: with an 'empty wax jig' and with a wax jig including the attachment. Archwires were not investigated as they are easily removed before a scan. Two radiologists evaluated the scans of each patient and each of the four areas under investigation: maxillary sinus, oral cavity, temporomandibular joints, and posterior cerebral fossa.

RESULTS

Stainless steel brackets always caused non-interpretability of all anatomic areas (100 per cent). Titanium brackets, ceramic brackets with metal slots, and stainless steel retainers caused artefact in the oral cavity only (for 20, 16.65, and 86.65 per cent of the subjects).

CONCLUSIONS/IMPLICATIONS: Our results show that ceramic brackets with metal slots and titanium brackets do not always have to be removed before MRI scans of the head and neck, depending on the area under investigation. Metal fixed retainers should only be removed if the oral cavity itself is under investigation. Stainless steel brackets should always be removed before MRI scans of the head and neck.

摘要

背景/目的:正畸矫治器在磁共振成像(MRI)扫描前常被移除,因为已知它们会产生伪影。本研究的目的是确定在对头颈部四个特定区域进行成像时,移除各种固定附件的确切指征。

材料/方法:60名因医疗原因需要进行头部MRI扫描的患者自愿参与本研究。将四种不同类型的固定附件(不锈钢托槽、钛托槽、带金属槽的陶瓷托槽和不锈钢保持器)中的一种分配给一名患者。每位患者在1.5T下进行两次扫描:一次使用“空蜡型”,另一次使用包含附件的蜡型。由于弓丝在扫描前很容易移除,因此未对其进行研究。两名放射科医生评估每位患者以及所研究的四个区域(上颌窦、口腔、颞下颌关节和后颅窝)的扫描结果。

结果

不锈钢托槽总是导致所有解剖区域无法解读(100%)。钛托槽、带金属槽的陶瓷托槽和不锈钢保持器仅在口腔中产生伪影(分别占受试者的20%、16.65%和86.65%)。

结论/启示:我们的结果表明,根据所研究的区域,带金属槽的陶瓷托槽和钛托槽在头颈部MRI扫描前不一定都要移除。只有在对口腔本身进行检查时,才应移除金属固定保持器。在对头颈部进行MRI扫描前,不锈钢托槽应始终移除。