• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

An exploratory study of using polygraph to detect deception in patients with traumatic brain injury.

作者信息

Li Gangqin, Hu Zeqing

机构信息

Department of Forensic Psychiatry, West China School of Preclinical and Forensic Medicine, Sichuan University, Sichuan, People's Republic of China.

出版信息

Neuroreport. 2014 Aug 20;25(12):943-7. doi: 10.1097/WNR.0000000000000217.

DOI:10.1097/WNR.0000000000000217
PMID:25006847
Abstract

To investigate the accuracy of the polygraph when used on patients with traumatic brain injury (TBI) and to analyze the factors influencing accuracy to enable provision of some field data for expert witnesses. Sixty patients with TBI (experimental group) and sixty normal individuals (control group) were tested by the polygraph with a Stimulation Test; responses of skin conductance, respiration, and finger pulse were recorded. The intelligence quotient of the experimental participants was measured and the factors influencing the accuracy of the polygraph test were analyzed. According to the computer automatic scoring, the overall accuracy was 76.7% for the control group; the accuracy of skin conductance, respiration, and finger pulse was 76.7, 35, and 18.7%, respectively, whereas for the experimental group, the overall accuracy was 56.7%. The accuracy of skin conductance, respiration, and finger pulse was 55.6, 23.3, and 25%, respectively. There was a significant difference in the overall accuracy between the two groups (P=0.020). According to the examiner's manual scoring, the overall accuracy was 86.7% for the control group and 61.7% for the experimental group (χ=9.786, P=0.002). The difference in accuracy obtained from the examiner and the computer was not significant. In the experimental group, the intelligence quotient of participants who had the right outcome was 63.2±10.9 and it was 55.3±9.5 for those who had the wrong outcome; this difference was significant (t=2.68, P=0.010).The accuracy of a polygraph test is much lower when it is used on patients with TBI compared with that of normal individuals. In actual application, full communication with the examinees should take place and their comprehension of the protocol should be evaluated. If participants can understand and co-operate with the test, the outcome can be considered reliable; if not, the outcome should not be relied on.

摘要

相似文献

1
An exploratory study of using polygraph to detect deception in patients with traumatic brain injury.
Neuroreport. 2014 Aug 20;25(12):943-7. doi: 10.1097/WNR.0000000000000217.
2
Effects of perceived efficacy and prospect of success on detection in the Guilty Actions Test.在有罪行为测试中,感知效力和成功前景对检测的影响。
Int J Psychophysiol. 2015 Jan;95(1):35-45. doi: 10.1016/j.ijpsycho.2014.12.010. Epub 2014 Dec 24.
3
New measures improve the accuracy of the directed-lie test when detecting deception using a mock crime.新措施提高了在使用模拟犯罪检测欺骗行为时定向测谎测试的准确性。
Physiol Behav. 2008 Jun 9;94(3):331-40. doi: 10.1016/j.physbeh.2008.01.022. Epub 2008 Feb 8.
4
Effect of biofeedback on the detection of deception.
J Forensic Sci. 1987 May;32(3):736-46.
5
The comparison question polygraph test: a contrast of methods and scoring.比较问题测谎仪测试:方法与评分的对比
Physiol Behav. 2015 May 1;143:15-26. doi: 10.1016/j.physbeh.2015.02.028. Epub 2015 Feb 20.
6
Capture by misleading information and its false acceptance in patients with traumatic brain injury.创伤性脑损伤患者被误导性信息俘获并错误接受该信息的情况。
Brain. 2006 Jan;129(Pt 1):128-40. doi: 10.1093/brain/awh664. Epub 2005 Nov 9.
7
Cross-modal physiological effects of electrodermal lability in the detection of deception.在欺骗检测中皮电反应性的跨模态生理效应。
J Pers Soc Psychol. 1981 Jun;40(6):1118-25. doi: 10.1037//0022-3514.40.6.1118.
8
A psychophysiological study of determinants for detection of deception.
Bull Tokyo Med Dent Univ. 1976 Mar;23(1):11-22.
9
Can simultaneously acquired electrodermal activity improve accuracy of fMRI detection of deception?同时获取的皮肤电活动能否提高功能磁共振成像检测欺骗行为的准确性?
Soc Neurosci. 2009;4(6):510-7. doi: 10.1080/17470910801907168.
10
Finger pulse waveform length in the detection of concealed information.用于检测隐藏信息的手指脉搏波形长度
Int J Psychophysiol. 2006 Aug;61(2):226-34. doi: 10.1016/j.ijpsycho.2005.10.005. Epub 2006 May 19.