PURPOSE

Although the VITA 3D-Master (3D) shade guide offers improved shade-matching performance, many dental materials are only available in VITA Classical (VC) shades. This study aimed to clarify whether it is possible to convert 3D shades determined by observers into VC shades (indirect method) without adding a clinically significant error in comparison with direct shade determination using the VC shade guide.

MATERIALS AND METHODS

Forty ceramic specimens were fabricated. Lab* values were recorded using a spectroradiometer. Sixty participants (35 dentists, 15 technicians, and 10 students) were recruited and asked to determine the shades of specimens using the VC and 3D shade guides under standardized conditions. Conversion tables were constructed by allocating the closest VC shade tab to every matched 3D shade and by use of an optimization algorithm (indirect methods). Differences between ΔE values for VC matches and for the indirect methods were evaluated using t tests.

RESULTS

A mean ΔE (SD) of 4.34 (2.00) for VC and 4.22 (2.21) for 3D was observed (P = .040). Compared with direct shade matching using VC, the indirect method with the optimized tables resulted in a mean ΔE of 4.32 (1.96), which was not significantly different (P = .586).

CONCLUSIONS

Within the limitations of this study, the conversion tables were suitable for the determination of tooth color using the 3D shade guide followed by conversion into VC shades without adding a clinically significant error.

摘要

目的

尽管VITA 3D-Master(3D)比色板提供了更好的比色性能,但许多牙科材料仅提供VITA经典(VC)色号。本研究旨在明确是否有可能将观察者确定的3D色号转换为VC色号(间接方法),与使用VC比色板直接比色相比,不增加临床上显著的误差。

材料与方法

制作了40个陶瓷标本。使用分光辐射度计记录Lab*值。招募了60名参与者(35名牙医、15名技师和10名学生),要求他们在标准化条件下使用VC和3D比色板确定标本的色号。通过为每个匹配的3D色号分配最接近的VC色片并使用优化算法(间接方法)构建转换表。使用t检验评估VC匹配和间接方法的ΔE值之间的差异。

结果

观察到VC的平均ΔE(标准差)为4.34(2.00),3D为4.22(2.21)(P = 0.040)。与使用VC直接比色相比,使用优化表的间接方法的平均ΔE为4.32(1.96),无显著差异(P = 0.586)。

结论

在本研究的局限性内,转换表适用于使用3D比色板确定牙齿颜色,然后转换为VC色号,而不会增加临床上显著的误差。