Abstract

Electrical stimulation has been suggested as a possible treatment for various functional gastrointestinal disorders (FGID). This paper presents a transcutaneous power supplied implantable electrical stimulation system. This technology solves the problem of supplying extended power to an implanted electrical stimulator. After implantation, the stimulation parameters can be reprogrammed by the external controller and then transmitted to the implanted stimulator. This would enable parametric studies to investigate the efficacy of various stimulation parameters in promoting gastrointestinal contractions. A pressure detector in the internal stimulator can provide real-time feedback about variations in the gastrointestinal tract. An optimal stimulation protocol leading to cecal contractions has been proposed: stimulation bursts of 3 ms pulse width, 10 V amplitude, 40 Hz frequency, and 20 s duration. The animal experiment demonstrated the functionality of the system and validated the effects of different stimulation parameters on cecal contractions.

摘要

电刺激被认为是治疗各种功能性胃肠疾病(FGID)的一种可能方法。本文提出了一种经皮供电的植入式电刺激系统。该技术解决了向植入式电刺激器提供扩展电源的问题。植入后,可以通过外部控制器重新编程刺激参数,然后将其传输到植入式刺激器。这将使参数研究能够研究各种刺激参数促进胃肠道收缩的效果。内部刺激器中的压力探测器可以提供有关胃肠道变化的实时反馈。已经提出了一种导致盲肠收缩的最佳刺激方案:刺激脉冲宽度为 3ms,幅度为 10V,频率为 40Hz,持续时间为 20s。动物实验证明了该系统的功能,并验证了不同刺激参数对盲肠收缩的影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/42c7/4099221/91d12acfcbb9/GRP2014-728572.001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验