BACKGROUND

Clostridum difficile is a gram-positive, spore-forming anaerobic bacillus that has substantial associated morbidity, mortality, and associated healthcare burdens. Clostridium difficile spores are not destroyed by alcohol. Alcohol gel dispensers are used commonly as the hand sanitization method of choice in hospitals. It is possible that gel dispensers are fomites for C. difficile.

METHODS

Thirty alcohol-based gel dispenser handles outside of rooms of patients with active C. difficile infection were sampled. The samples were assessed for C. difficile by both culture and polymerase chain reaction (PCR). The samples were also assessed for other organisms by culture.

RESULTS

No C. difficile was cultured or detected by PCR on any of the gel dispensers. Coagulase-negative Staphyloccus spp., diptheroids, and Bacillus spp. were the organisms detected most commonly.

CONCLUSION

At our institution, C. difficile is not present on alcohol-based gel dispensers, but other potentially pathogenis are.

摘要

背景

艰难梭菌是一种革兰氏阳性、形成芽孢的厌氧杆菌,会引发严重的发病情况、死亡率以及相关的医疗负担。艰难梭菌芽孢不会被酒精破坏。酒精凝胶分配器在医院中通常被用作首选的手部消毒方法。凝胶分配器有可能是艰难梭菌的传播媒介。

方法

对30个处于艰难梭菌活跃感染患者病房外的酒精基凝胶分配器把手进行采样。通过培养和聚合酶链反应(PCR)对样本进行艰难梭菌评估。还通过培养对样本中的其他微生物进行评估。

结果

在任何凝胶分配器上均未通过培养或PCR检测到艰难梭菌。凝固酶阴性葡萄球菌属、类白喉杆菌和芽孢杆菌属是最常检测到的微生物。

结论

在我们机构,酒精基凝胶分配器上不存在艰难梭菌,但存在其他潜在病原体。