Lee Jin Ho, Kim Dong Wook, Kim Eun Na, Park Seok-Won, Kim Hee-Bok, Oh Se Heang, Kwon Seong Keun
Department of Advanced Materials, Hannam University, Daejeon, Republic of Korea.
Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.
Otolaryngol Head Neck Surg. 2014 Nov;151(5):830-5. doi: 10.1177/0194599814549527. Epub 2014 Sep 11.
Poly(lactic-co-glycolic acid) (PLGA) is an aliphatic polyester and one of the most commonly used synthetic biodegradable polymers for tissue engineering. The objectives of this study were to evaluate the biocompatibility of PLGA/Pluronic F127 in the vocal fold.
A randomized, prospective, controlled animal study.
University laboratory.
We used 18 New Zealand white rabbits, which were divided into 5% PLGA solution (n = 9) and 10% PLGA solution (n = 9) groups. The PLGA/Pluronic F127 solutions were injected into the rabbit vocal fold. Laryngoscopic exams were performed at 1, 4, and 8 weeks after implantation; then larynx specimens were sampled. High-speed video camera examination was performed for functional analysis of vocal mucosa vibration at 8 weeks after implantation. Also, we evaluated the amplitude of the mucosal wave from the laryngeal midline on high-speed recording. Histologic study of larynx specimen was performed at 4 and 8 weeks.
All animals survived until the scheduled period. Laryngoscopic analysis showed that both 5% and 10% PLGA/Pluronic F127 maintained after 8 weeks after injection without significant inflammatory response. On functional analysis, high-speed camera examination revealed regular and symmetric contact of vocal fold mucosa without a distorted movement by injected PLGA/Pluronic F127. Histologically, no significant inflammation was observed in the injected vocal fold.
As a vocal fold injection material, PLGA/Pluronic F127 showed a good bio-compatibility without significant inflammatory response. Further experiment will follow to elucidate its role for drug or gene delivery into the vocal fold.
聚乳酸-乙醇酸共聚物(PLGA)是一种脂肪族聚酯,是组织工程中最常用的合成可生物降解聚合物之一。本研究的目的是评估PLGA/普朗尼克F127在声带中的生物相容性。
一项随机、前瞻性、对照动物研究。
大学实验室。
我们使用了18只新西兰白兔,将其分为5%PLGA溶液组(n = 9)和10%PLGA溶液组(n = 9)。将PLGA/普朗尼克F127溶液注射到兔声带中。在植入后1、4和8周进行喉镜检查;然后采集喉部标本。在植入后8周进行高速摄像机检查以对声带黏膜振动进行功能分析。此外,我们在高速记录中评估了喉中线处黏膜波的振幅。在4周和8周对喉部标本进行组织学研究。
所有动物均存活至预定时间。喉镜分析显示,注射后8周,5%和10%的PLGA/普朗尼克F127均保持良好,无明显炎症反应。功能分析显示,高速摄像机检查发现声带黏膜接触规律且对称,注射的PLGA/普朗尼克F127未导致运动变形。组织学检查显示,注射的声带未观察到明显炎症。
作为一种声带注射材料,PLGA/普朗尼克F127显示出良好的生物相容性,无明显炎症反应。后续将进行进一步实验以阐明其在声带药物或基因递送中的作用。