Suppr超能文献

11.7T下足趾屈肌腱滑车的磁共振成像

Magnetic resonance imaging of the pulleys of the flexor tendons of the toes at 11.7 T.

作者信息

Tafur Monica, Iwasaki Kenyu, Statum Sheronda, Chung Christine B, Szeverenyi Nikolaus M, Bydder Graeme M

机构信息

Department of Radiology, University of California, San Diego, School of Medicine, 408 Dickinson St., San Diego, CA, 92103-8226, USA,

出版信息

Skeletal Radiol. 2015 Jan;44(1):87-95. doi: 10.1007/s00256-014-2019-y. Epub 2014 Oct 2.

Abstract

OBJECTIVE

We obtained high-resolution 11.7-T MR images of the pulleys of the flexor tendons in cadaveric toe specimens. A detailed understanding of toe pulley anatomy as seen with MR is likely to be of benefit in recognizing disease and the effects of trauma.

MATERIAL AND METHODS

Six cadaveric toes were imaged with an 11.7-T small-bore MR imaging system using optimized coils. Two-dimensional dual-echo SE scans were obtained in three planes (40 × 40 × 400-μm(3) voxel size, TE = 7/14 ms, TR = 3,500 ms, fat saturation). Three-dimensional spoiled gradient echo scans were obtained (90-150 μm(3) isotropic voxel size, TE = 6 ms, TR = 25 ms, with and without fat saturation). Specimen orientation was with the long axis of the toe either parallel or perpendicular to B0.

RESULTS

All the annular (A) pulleys were demonstrated in the great and lesser toes. The A2 pulley in the great and lesser toes and the A4 pulley in the lesser toes were the most substantial pulleys. The A5 pulley, which has not previously been described in the toes, was demonstrated. The cruciform pulleys were also seen and were smaller and thinner. Three tissue layers were seen, and there was evidence of different fiber directions in annular pulleys producing different magic angle effects.

CONCLUSION

Detailed anatomy of the pulley system of the flexor tendons was seen on the 11.7-T MR images showing new features and providing a basis for image interpretation. Similarities and differences between the pulley systems in the toes and the fingers were identified.

摘要

目的

我们获取了尸体脚趾标本中屈肌腱滑车的高分辨率11.7-T磁共振(MR)图像。通过MR详细了解脚趾滑车的解剖结构可能有助于识别疾病和创伤的影响。

材料与方法

使用优化线圈,通过11.7-T小口径MR成像系统对6个尸体脚趾进行成像。在三个平面上进行二维双回波SE扫描(体素大小为40×40×400-μm³,TE = 7/14 ms,TR = 3500 ms,脂肪饱和)。进行三维扰相梯度回波扫描(各向同性体素大小为90-150-μm³,TE = 6 ms,TR = 25 ms,有或无脂肪饱和)。标本的取向是使脚趾的长轴与B0平行或垂直。

结果

在大脚趾和小脚趾中均显示出所有的环形(A)滑车。大脚趾和小脚趾中的A2滑车以及小脚趾中的A4滑车是最明显的滑车。显示出之前未在脚趾中描述过的A5滑车。十字形滑车也可见,且更小更薄。观察到三层组织,并且有证据表明环形滑车中不同的纤维方向会产生不同的魔角效应。

结论

在11.7-T MR图像上可以看到屈肌腱滑车系统的详细解剖结构,显示出新的特征并为图像解读提供了基础。确定了脚趾和手指滑车系统之间的异同。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验