Department of Chemistry, The University of Hull , Cottingham Road, Hull, HU6 7RX, United Kingdom.
Anal Chem. 2014 Nov 4;86(21):10552-9. doi: 10.1021/ac5023265. Epub 2014 Oct 16.
We demonstrate the application of a multilaminar flow platform, in which functionalized magnetic particles are deflected through alternating laminar flow streams of reagents and washing solutions via an external magnet, for the rapid detection of the inflammatory biomarker, C-reactive protein (CRP). The two-step sandwich immunoassay was accomplished in less than 60 s, a vast improvement on the 80-300 min time frame required for enzyme-linked immunosorbent assays (ELISA) and the 50 min necessary for off-chip magnetic particle-based assays. The combination of continuous flow and a stationary magnet enables a degree of autonomy in the system, while a detection limit of 0.87 μg mL(-1) makes it suitable for the determination of CRP concentrations in clinical diagnostics. Its applicability was further proven by assaying real human serum samples and comparing those results to values obtained using standard ELISA tests.
我们展示了一种多层流平台的应用,其中功能化的磁性颗粒在外磁场的作用下通过交替的层流试剂和洗涤溶液流进行偏转,用于快速检测炎症生物标志物 C 反应蛋白(CRP)。两步夹心免疫测定在不到 60 s 内完成,这大大缩短了酶联免疫吸附测定(ELISA)所需的 80-300 min 时间框架,以及基于芯片外磁性颗粒的测定所需的 50 min。连续流和固定磁铁的结合使系统具有一定程度的自主性,而 0.87μgmL(-1)的检测限使其适用于临床诊断中 CRP 浓度的测定。通过检测真实的人血清样本并将这些结果与使用标准 ELISA 测试获得的值进行比较,进一步证明了其适用性。