Barnes Charles S, Allenbrand Ryan, Mohammed Mubeen, Gard Luke, Pacheco Freddy, Kennedy Kevin, Portnoy Jay M, Ciaccio Christine
The Children's Mercy Hospital, Kansas City, Missouri.
The Children's Mercy Hospital, Kansas City, Missouri.
Ann Allergy Asthma Immunol. 2015 Mar;114(3):221-5. doi: 10.1016/j.anai.2014.10.015. Epub 2014 Nov 18.
Exposure assessment is an important component of allergic disease diagnosis and management. Analysis for allergen content in vacuumed dust has been used traditionally.
To study allergen levels of dust taken from high-efficiency furnace filters in Midwestern homes.
Furnace filters used were FQT12 1-inch disposable filters with high-efficiency media placed in homes enrolled in the Kansas City Safe and Healthy Homes Project. Dust was removed from the filters by vacuuming. Fungal culture was used to obtain counts of viable spores. Aeroallergens Fel d1, Can f1, Mus m1, Der f1, Der p1, and Bla g2 and antigenic material from Alternaria, Aspergillus, Cladosporium, and Penicillium species were measured using commercially available immunoassay materials.
Sixty filters were recovered from 56 homes after an average 135 days in situ. Mean weight of dust recovered was 2.43 g and correlated well with the time the filter was in place. Viable spore counts ranged to 4.8 × 10(7) per gram of dust. Mean fungal antigenic material ranged to 42 μg per gram for Cladosporium species. Mean aeroallergen material ranged to 7 μg per gram for Fel d1. Aeroallergen measurements were above the level of detection in 100% of houses for Fel d1 and 89% of houses for Bla g2. Levels of Fel d1 and Can f1 were strongly positively correlated.
Allergens from 5 common aeroallergen species and antigenic material from 4 common fungal taxa can be measured in dust taken from high-efficiency furnace filters.
暴露评估是变应性疾病诊断和管理的重要组成部分。传统上一直采用分析真空吸尘灰尘中的变应原含量。
研究从美国中西部家庭高效炉过滤器采集的灰尘中的变应原水平。
所使用的炉过滤器为FQT12 1英寸一次性过滤器,带有高效过滤介质,放置在堪萨斯城安全健康家庭项目所登记的家庭中。通过吸尘从过滤器上清除灰尘。采用真菌培养来获取活孢子计数。使用市售免疫分析材料测量气传变应原猫毛蛋白、犬小孢子菌变应原1、小鼠蛋白1、屋尘螨变应原1、粉尘螨变应原1和支气管哮喘变应原2以及链格孢属、曲霉属、枝孢属和青霉属物种的抗原物质。
在原位平均135天后,从56个家庭中回收了60个过滤器。回收灰尘的平均重量为2.43克,与过滤器放置的时间密切相关。每克灰尘中活孢子计数范围达4.8×10⁷ 。枝孢属物种的平均真菌抗原物质范围达每克42微克。猫毛蛋白的平均气传变应原物质范围达每克7微克。在100%的房屋中猫毛蛋白和气传变应原测量值高于检测水平,在89%的房屋中支气管哮喘变应原2高于检测水平。猫毛蛋白和犬小孢子菌变应原1的水平呈强正相关。
可在从高效炉过滤器采集的灰尘中测量5种常见气传变应原物种的变应原以及4种常见真菌类群的抗原物质。