Suppr超能文献

通过硅烷化实现壳聚糖对钛表面的功能化:细胞生物相容性行为的三维共聚焦激光扫描显微镜成像

Functionalization of titanium surface with chitosan via silanation: 3D CLSM imaging of cell biocompatibility behaviour.

作者信息

Attik G N, D'Almeida M, Toury B, Grosgogeat B

机构信息

Université de Lyon.

出版信息

Bull Group Int Rech Sci Stomatol Odontol. 2013 Sep 16;52(1):e35-44.

Abstract

INTRODUCTION

Biocompatibility ranks as one of the most important properties of dental materials. One of the criteria for biocompatibility is the absence of material toxicity to cells, according to the ISO 7405 and 10993 recommendations. Among numerous available methods for toxicity assessment; 3-dimensional Confocal Laser Scanning Microscopy (3D CLSM) imaging was chosen because it provides an accurate and sensitive index of living cell behavior in contact with chitosan coated tested implants.

OBJECTIVES

The purpose of this study was to investigate the in vitro biocompatibility of functionalized titanium with chitosan via a silanation using sensitive and innovative 3D CLSM imaging as an investigation method for cytotoxicity assessment.

METHODS

The biocompatibility of four samples (controls cells, TA6V, TA6V-TESBA and TA6V-TESBAChitosan) was compared in vitro after 24h of exposure. Confocal imaging was performed on cultured human gingival fibroblast (HGF1) like cells using Live/Dead® staining. Image series were obtained with a FV10i confocal biological inverted system and analyzed with FV10-ASW 3.1 Software (Olympus France).

RESULTS

Image analysis showed no cytotoxicity in the presence of the three tested substrates after 24 h of contact. A slight decrease of cell viability was found in contact with TA6V-TESBA with and without chitosan compared to negative control cells.

CONCLUSION

Our findings highlighted the use of 3D CLSM confocal imaging as a sensitive method to evaluate qualitatively and quantitatively the biocompatibility behavior of functionalized titanium with chitosan via a silanation. The biocompatibility of the new functionalized coating to HGF1 cells is as good as the reference in biomedical device implantation TA6V.

摘要

引言

生物相容性是牙科材料最重要的特性之一。根据ISO 7405和10993建议,生物相容性的标准之一是材料对细胞无毒性。在众多可用的毒性评估方法中,选择了三维共聚焦激光扫描显微镜(3D CLSM)成像,因为它能提供与壳聚糖涂层测试植入物接触的活细胞行为的准确且灵敏指标。

目的

本研究的目的是通过硅烷化处理,使用灵敏且创新的3D CLSM成像作为细胞毒性评估的研究方法,来研究功能化钛与壳聚糖的体外生物相容性。

方法

在暴露24小时后,体外比较四个样品(对照细胞、TA6V、TA6V-TESBA和TA6V-TESBA壳聚糖)的生物相容性。使用活/死染色对培养的人牙龈成纤维细胞(HGF1)样细胞进行共聚焦成像。使用FV10i共聚焦生物倒置系统获取图像系列,并使用FV10-ASW 3.1软件(法国奥林巴斯)进行分析。

结果

图像分析显示,接触24小时后,在三种测试底物存在的情况下均无细胞毒性。与阴性对照细胞相比,接触有或没有壳聚糖的TA6V-TESBA时,细胞活力略有下降。

结论

我们的研究结果突出了3D CLSM共聚焦成像作为一种灵敏方法的应用,可定性和定量评估通过硅烷化处理的功能化钛与壳聚糖的生物相容性行为。新功能化涂层对HGF1细胞的生物相容性与生物医学设备植入中的参考材料TA6V一样好。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验