Suppr超能文献

在混合SPECT/CT系统中使用CT引导的感兴趣区(ROI)对纹状体多巴胺转运体可用性进行半定量分析的可行性。

The feasibility of using CT-guided ROI for semiquantifying striatal dopamine transporter availability in a hybrid SPECT/CT system.

作者信息

Hsu Chien-Chin, Chang Yen-Hsiang, Lin Wei-Che, Tang Shu-Wen, Wang Pei-Wen, Huang Yung-Cheng, Chiu Nan-Tsing

机构信息

Department of Nuclear Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 123 Dapi Road, Niaosong District, Kaohsiung City 83301, Taiwan.

Department of Diagnostic Radiology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 123 Dapi Road, Niaosong District, Kaohsiung City 83301, Taiwan.

出版信息

ScientificWorldJournal. 2014;2014:879497. doi: 10.1155/2014/879497. Epub 2014 Nov 2.

Abstract

A hybrid SPECT/CT system provides accurate coregistration of functional and morphological images. CT-guided region of interest (ROI) for semiquantifying striatal dopamine transporter (DAT) availability may be a feasible method. We therefore assessed the intra- and interobserver reproducibility of manual SPECT and CT-guided ROI methods and compared their semiquantitative data with data from MRI-guided ROIs. We enrolled twenty-eight patients who underwent Tc-99m TRODAT-1 brain SPECT/CT and brain MRI. ROIs of the striatal, caudate, putamen, and occipital cortex were manually delineated on the SPECT, CT, and MRI. ROIs from CT and MRI were transferred to the coregistered SPECT for semiquantification. The striatal, caudate, and putamen nondisplaceable binding potential (BPND) were calculated. Using CT-guided ROIs had higher intra- and interobserver concordance correlation coefficients, closer Bland-Altman biases to zero, and narrower limits of agreement than using manual SPECT ROIs. The correlation coefficients of striatal, caudate, and putamen BPND were good between manual SPECT and MRI-guided ROI methods and even better between CT-guided and MRI-guided ROI methods. Conclusively, CT-guided ROI delineation for semiquantifying striatal DAT availability in a hybrid SPECT/CT system is highly reproducible, and the semiquantitative data correlate well with data from MRI-guided ROIs.

摘要

混合型单光子发射计算机断层扫描/计算机断层扫描(SPECT/CT)系统可实现功能图像与形态图像的精确配准。利用CT引导的感兴趣区(ROI)对纹状体多巴胺转运体(DAT)可用性进行半定量分析可能是一种可行的方法。因此,我们评估了手动SPECT和CT引导的ROI方法在观察者内和观察者间的可重复性,并将它们的半定量数据与MRI引导的ROI数据进行比较。我们纳入了28例接受过锝-99m TRODAT-1脑SPECT/CT和脑MRI检查的患者。在SPECT、CT和MRI上手动勾勒出纹状体、尾状核、壳核和枕叶皮质的ROI。将CT和MRI上的ROI转移到配准后的SPECT上进行半定量分析。计算纹状体、尾状核和壳核的不可置换结合潜能(BPND)。与使用手动SPECT ROI相比,使用CT引导的ROI在观察者内和观察者间具有更高的一致性相关系数、更接近零的Bland-Altman偏差以及更窄的一致性界限。手动SPECT和MRI引导的ROI方法之间纹状体、尾状核和壳核BPND的相关系数良好,而CT引导和MRI引导的ROI方法之间的相关系数更好。总之,在混合型SPECT/CT系统中,利用CT引导的ROI勾勒技术对纹状体DAT可用性进行半定量分析具有高度可重复性,且半定量数据与MRI引导的ROI数据具有良好的相关性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c887/4233671/c3351a98879b/TSWJ2014-879497.001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验