Suppr超能文献

乳胶和乙烯基检查手套。质量控制程序及其对医护人员的影响。

Latex and vinyl examination gloves. Quality control procedures and implications for health care workers.

作者信息

Kotilainen H R, Brinker J P, Avato J L, Gantz N M

机构信息

Infection Control Department, University of Massachusetts Medical Center, Worcester 01655.

出版信息

Arch Intern Med. 1989 Dec;149(12):2749-53. doi: 10.1001/archinte.149.12.2749.

Abstract

In December 1987, we investigated an increased number of cases of herpetic whitlow in medical intensive care unit nurses who routinely gloved for secretion contact. One particular brand of vinyl examination glove had been used in the medical intensive care unit. Restriction endonuclease mapping established the similarity of employee isolates with one patient isolate of herpes simplex virus type I. When initial viral assay demonstrated 2.5% to 10% penetration of herpes simplex virus type I across unused gloves, an evaluation of glove quality was undertaken. In a 300-mL watertightness test, seven brands of vinyl gloves failed 4% to 28% (average, 11.1%; 132/1200), while seven brands of latex gloves failed 0% to 2.6% (average, 1.4%; 24/1750). The brand of vinyl glove that had been in use in the medical intensive care unit failed 28% of the time. Watertight gloves were then tested for permeability to herpes simplex virus type I. None of the latex gloves failed (n = 1726), while only 10 of the vinyl gloves failed (n = 1068, 0.95%). Extreme variability in glove quality was observed. However, gloves made from intact vinyl may provide similar protectiveness as those made from intact latex. As the demand for gloves increases, emphasis should be placed on the production of plentiful, better quality latex and vinyl gloves.

摘要

1987年12月,我们对医疗重症监护病房的护士中疱疹性瘭疽病例数增加的情况进行了调查,这些护士在接触分泌物时通常戴手套。医疗重症监护病房使用了某一特定品牌的乙烯基检查手套。限制性内切酶图谱分析确定了员工分离株与1例I型单纯疱疹病毒患者分离株的相似性。当最初的病毒检测显示I型单纯疱疹病毒能穿透2.5%至10%的未使用手套时,我们对手套质量进行了评估。在一项300毫升的防水性测试中,7个品牌的乙烯基手套有4%至28%(平均11.1%,132/1200)出现漏水,而7个品牌的乳胶手套有0%至2.6%(平均1.4%,24/1750)出现漏水。医疗重症监护病房一直在使用的那个品牌的乙烯基手套有28%的时候出现漏水。随后对防水手套进行了I型单纯疱疹病毒渗透性测试。没有乳胶手套出现渗漏(n = 1726),而乙烯基手套只有10个出现渗漏(n = 1068,0.95%)。观察到手套质量存在极大差异。然而,完好的乙烯基制成的手套可能与完好的乳胶制成的手套提供相似的防护性。随着对手套需求的增加,应着重生产充足且质量更好的乳胶手套和乙烯基手套。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验