Suppr超能文献

[使用德国海德堡工程公司的Spectralis频域光学相干断层扫描技术进行新的神经视网膜边缘分析。初步研究]

[New neuroretinal rim analysis with spectral domain optical coherence tomography, Spectralis (Heidelberg Engineering, Germany). Preliminary study].

作者信息

El Chehab H, Delbarre M, Maréchal M, Rosenberg R, Marill A-F, Fénolland J-R, Renard J-P

机构信息

Service d'ophtalmologie, HIA Val-de-Grâce, 74, boulevard Port-Royal, 75013 Paris, France.

Service d'ophtalmologie, HIA Val-de-Grâce, 74, boulevard Port-Royal, 75013 Paris, France.

出版信息

J Fr Ophtalmol. 2015 Jan;38(1):46-52. doi: 10.1016/j.jfo.2014.10.004. Epub 2015 Jan 6.

Abstract

INTRODUCTION

Clinical determination of the outer limits of the optic disk (OD) doesn't always correspond to the true anatomic limits of the optic nerve head (ONH) defined by the Bruch's membrane opening (BMO). A new index analyzing the OD with optical coherence tomography (OCT), "minimal rim width" (BMO-MRW), evaluates the smallest thickness of the neuroretinal rim between the BMO and the internal limiting membrane. The purpose of this study was to evaluate new software for automatic measurement of the BMO-MRW.

MATERIALS AND METHODS

This study investigated 95 eyes: 40 control eyes and 55 eyes followed and treated for primary open angle glaucoma (42 early glaucoma, 7 moderate glaucoma and 6 advanced glaucoma). After a precise localization of the OD center, 24 radial scans of the ONH are taken with the Spectralis OCT (Heidelberg Engineering, Germany). From the 48 measurements of BMO-MRW, the mean thickness as well as that in each of the 6 papillary sectors of this new index are calculated. ROC curves analysis (receiver operating characteristic) was used to assess the diagnostic capabilities of the various parameters.

RESULTS

Thicknesses of all parameters were statistically lower in glaucoma than in controls. The mean value and inferotemporal sector (IT) had the best diagnostic capabilities without significant difference between them (BMO-MRW-average = 0.890 ± 0.062, BMO-MRW-IT = 0.881 ± 0.066, P = 0.59). The area under the curve was lowest in the temporal sector (0.820 ± 086 statistically lower than the average value, P = 0.04).

CONCLUSIONS

This preliminary study of a new automated analysis of the neuroretinal rim highlights the diagnostic value of the BMO-MRW index. This evaluation appears to be best correlated with the anatomy of the ONH with good diagnostic sensitivity.

摘要

引言

视盘(OD)外部界限的临床判定并不总是与由布鲁赫膜开口(BMO)所定义的视神经乳头(ONH)的真正解剖学界限相对应。一种利用光学相干断层扫描(OCT)分析视盘的新指标“最小边缘宽度”(BMO-MRW),用于评估BMO与内界膜之间神经视网膜边缘的最小厚度。本研究的目的是评估用于自动测量BMO-MRW的新软件。

材料与方法

本研究调查了95只眼睛:40只对照眼以及55只接受原发性开角型青光眼随访和治疗的眼睛(42只早期青光眼、7只中度青光眼和6只晚期青光眼)。在对视盘中心进行精确定位后,使用德国海德堡工程公司的Spectralis OCT对视神经乳头进行24次径向扫描。从48次BMO-MRW测量值中,计算出该新指标的平均厚度以及在6个视乳头扇形区域中每个区域的厚度。采用ROC曲线分析(受试者工作特征曲线)来评估各种参数的诊断能力。

结果

青光眼患者所有参数的厚度在统计学上均低于对照组。平均值和颞下扇形区域(IT)具有最佳的诊断能力,两者之间无显著差异(BMO-MRW平均值 = 0.890 ± 0.062,BMO-MRW-IT = 0.881 ± 0.066,P = 0.59)。曲线下面积在颞侧扇形区域最低(0.820 ± 0.086,在统计学上低于平均值,P = 0.04)。

结论

这项对神经视网膜边缘进行新的自动分析的初步研究突出了BMO-MRW指标的诊断价值。该评估似乎与视神经乳头的解剖结构具有最佳相关性,且具有良好的诊断敏感性。