双谱指数(BIS)监测可能在全身麻醉期间自动无创血压(NIBP)测量之前检测到严重低血压:一例病例报告。

BiSpectral Index (BIS) monitoring may detect critical hypotension before automated non-invasive blood pressure (NIBP) measurement during general anaesthesia; a case report.

作者信息

Smith Matthew M J

机构信息

Department of Anaesthetics, Sheffield Teaching Hospitals, Sheffield, S10 2JF, UK.

出版信息

F1000Res. 2014 Jan 9;3:5. doi: 10.12688/f1000research.3-5.v1. eCollection 2014.

Abstract

A patient undergoing general anaesthesia for neurosurgery exhibited an unexpected sudden decrease in the BiSpectral Index (BIS) value to near-zero. This prompted the detection of profound hypotension using non-invasive blood pressure (NIBP) measurement and expedited urgent assessment and treatment, with the patient making a full recovery. Widely regarded as a 'depth of anaesthesia' monitor, this case demonstrates the potential extra clinical benefit BIS may have in the detection of critical incidents such as anaphylaxis during general anaesthesia.

摘要

一名接受神经外科全身麻醉的患者,其脑电双频指数(BIS)值意外突然降至接近零。这促使通过无创血压(NIBP)测量发现了严重低血压,并加快了紧急评估和治疗,患者最终完全康复。BIS被广泛视为“麻醉深度”监测指标,该病例表明BIS在检测全身麻醉期间过敏反应等危急事件方面可能具有额外的临床益处。