Plethysmographic measurement of haemoglobin concentration ([Formula: see text]), pleth variability index (PVI), and perfusion index (PI) with the Radical-7 apparatus is growing in popularity. Previous studies have indicated that [Formula: see text] has poor precision, particularly when PI is low. We wanted to study the effects of a sympathetic block on these measurements.
Twenty patients underwent hand surgery under brachial plexus block with one Radical-7 applied to each arm. Measurements were taken up to 20 min after the block had been initiated. Venous blood samples were also drawn from the non-blocked arm.
During the last 10 min of the study, [Formula: see text] had increased by 8.6%. The PVI decreased by 54%, and PI increased by 188% in the blocked arm (median values). All these changes were statistically significant. In the non-blocked arm, these parameters did not change significantly.
Brachial plexus block significantly altered [Formula: see text], PVI, and PI, which indicates that regional nervous control of the arm greatly affects plethysmographic measurements obtained by the Radical-7. After the brachial plexus block, [Formula: see text] increased and PVI decreased.
使用 Radical-7 仪器进行血红蛋白浓度([公式:见文本])、搏动变异指数(PVI)和灌注指数(PI)的容积描记法测量越来越受欢迎。先前的研究表明,[公式:见文本]的精度较差,特别是当 PI 较低时。我们想研究交感神经阻滞对这些测量的影响。
20 名患者在手臂丛神经阻滞下接受手部手术,每只手臂应用一个 Radical-7。在阻滞开始后最多 20 分钟进行测量。还从未阻滞的手臂抽取静脉血样本。
在研究的最后 10 分钟,[公式:见文本]增加了 8.6%。在阻滞的手臂中,PVI 下降了 54%,PI 增加了 188%(中位数)。所有这些变化均具有统计学意义。在未阻滞的手臂中,这些参数没有明显变化。
臂丛神经阻滞显著改变了[公式:见文本]、PVI 和 PI,这表明手臂的区域神经控制对 Radical-7 获得的容积描记法测量有很大影响。臂丛神经阻滞后,[公式:见文本]增加,PVI 降低。