OBJECTIVES

To evaluate carboxyhemoglobin (COHb) values measured with a CO-oximeter (Roche-cobas b 221) in jaundiced newborns with or without hemolysis and healthy controls in order to assess whether COHb measurement determined with a CO-oximeter could be used as an indicator of hemolysis in newborns with ABO alloimmunization.

METHODS

A total of 86 term newborn infants were prospectively studied. The study cohort consisted of three subgroups: 18 infants with ABO HDN, 21 infants with hyperbilirubinemia without hemolytic disease who required phototherapy, and 47 healthy controls. The COHb, bilirubin, and Hb levels were measured.

RESULTS

The three subgroups did not differ significantly with respect to birth weight, gestational age, gender, Apgar score, or mode of delivery. The ABO HDN infants had significantly higher COHb values than the healthy controls (median 2.4% versus 1.3%, p < 0.0005) and the group with hyperbilirubinemia without hemolytic disease (median 2.4% versus 1.3%, p < 0.0005), although the infants with hyperbilirubinemia without hemolytic disease did not have significantly higher COHb values compared with the healthy controls. The cut-off value of 1.7% COHb had 72% sensitivity and 97% specificity for confirming hemolysis in ABO alloimmunization.

CONCLUSIONS

Our data show that COHb values determined with CO-oximeters are higher in newborns with hemolysis than in those without hemolysis. COHb measured with CO-oximeters could be used to confirm hemolysis in infants with ABO alloimmunization.

摘要

目的

评估经一氧化碳血氧仪(罗氏cobas b 221)测量的黄疸新生儿(有或无溶血)及健康对照者的碳氧血红蛋白(COHb)值,以评估用一氧化碳血氧仪测定的COHb测量值是否可作为ABO血型同种免疫新生儿溶血的指标。

方法

前瞻性研究共纳入86名足月儿。研究队列包括三个亚组:18名ABO溶血病新生儿、21名需要光疗的无溶血性疾病的高胆红素血症新生儿和47名健康对照者。测量COHb、胆红素和血红蛋白水平。

结果

三个亚组在出生体重、胎龄、性别、阿氏评分或分娩方式方面无显著差异。ABO溶血病新生儿的COHb值显著高于健康对照者(中位数2.4%对1.3%,p < 0.0005)和无溶血性疾病的高胆红素血症组(中位数2.4%对1.3%,p < 0.0005),尽管无溶血性疾病的高胆红素血症婴儿的COHb值与健康对照者相比无显著升高。COHb值为1.7%时,用于确认ABO血型同种免疫溶血的敏感性为72%,特异性为97%。

结论

我们的数据表明,溶血新生儿经一氧化碳血氧仪测定的COHb值高于无溶血新生儿。用一氧化碳血氧仪测量的COHb可用于确认ABO血型同种免疫婴儿的溶血情况。