Chen Liu Qi, Randtke Edward A, Jones Kyle M, Moon Brianna F, Howison Christine M, Pagel Mark D
Department of Chemistry and Biochemistry, University of Arizona, Tucson, AZ, USA.
Mol Imaging Biol. 2015 Aug;17(4):488-96. doi: 10.1007/s11307-014-0816-2.
We aimed to develop pixelwise maps of tumor acidosis to aid in evaluating extracellular tumor pH (pHe) in cancer biology.
MCF-7 and MDA-MB-231 mouse models were imaged during a longitudinal study. AcidoCEST MRI and a series of image processing methods were used to produce parametric maps of tumor pHe, and tumor pHe was also measured with a pH microsensor.
Sufficient contrast-to-noise for producing pHe maps was achieved by using standard image processing methods. A comparison of pHe values measured with acidoCEST MRI and a pH microsensor showed that acidoCEST MRI measured tumor pHe with an accuracy of 0.034 pH units. The MCF-7 tumor model was found to be more acidic compared to the MDA-MB-231 tumor model. The pHe was not related to tumor size during the longitudinal study.
These results show that acidoCEST MRI can create pixelwise tumor pHe maps of mouse models of cancer.
我们旨在绘制肿瘤酸中毒的逐像素地图,以辅助评估癌症生物学中的细胞外肿瘤pH值(pHe)。
在一项纵向研究中对MCF-7和MDA-MB-231小鼠模型进行成像。使用酸化学交换饱和转移磁共振成像(AcidoCEST MRI)和一系列图像处理方法来生成肿瘤pHe的参数地图,并且还用pH微传感器测量肿瘤pHe。
通过使用标准图像处理方法,获得了用于生成pHe地图的足够的对比度噪声比。用AcidoCEST MRI和pH微传感器测量的pHe值比较表明,AcidoCEST MRI测量肿瘤pHe的准确度为0.034个pH单位。发现MCF-7肿瘤模型比MDA-MB-231肿瘤模型酸性更强。在纵向研究期间,pHe与肿瘤大小无关。
这些结果表明,AcidoCEST MRI可以创建癌症小鼠模型的逐像素肿瘤pHe地图。