两种用于测量肿瘤细胞外pH值的酸性CEST MRI造影剂碘普罗胺和碘帕醇的比较。

A comparison of iopromide and iopamidol, two acidoCEST MRI contrast media that measure tumor extracellular pH.

作者信息

Moon Brianna F, Jones Kyle M, Chen Liu Qi, Liu Peilu, Randtke Edward A, Howison Christine M, Pagel Mark D

机构信息

Department of Biomedical Engineering, University of Arizona, Tucson, AZ, USA.

Biomedical Engineering Graduate Interdisciplinary Program, University of Arizona, Tucson, AZ, USA.

出版信息

Contrast Media Mol Imaging. 2015 Nov-Dec;10(6):446-55. doi: 10.1002/cmmi.1647. Epub 2015 Jun 25.

Abstract

Acidosis within tumor and kidney tissues has previously been quantitatively measured using a molecular imaging technique known as acidoCEST MRI. The previous studies used iopromide and iopamidol, two iodinated contrast agents that are approved for clinical CT diagnoses and have been repurposed for acidoCEST MRI studies. We aimed to compare the performance of the two agents for measuring pH by optimizing image acquisition conditions, correlating pH with a ratio of CEST effects from an agent, and evaluating the effects of concentration, endogenous T1 relaxation time and temperature on the pH-CEST ratio correlation for each agent. These results showed that the two agents had similar performance characteristics, although iopromide produced a pH measurement with a higher dynamic range while iopamidol produced a more precise pH measurement. We then compared the performance of the two agents to measure in vivo extracellular pH (pHe) within xenograft tumor models of Raji lymphoma and MCF-7 breast cancer. Our results showed that the pHe values measured with each agent were not significantly different. Also, iopromide consistently measured a greater region of the tumor relative to iopamidol in both tumor models. Therefore, an iodinated contrast agent for acidoCEST MRI should be selected based on the measurement properties needed for a specific biomedical study and the pharmacokinetic properties of a specific tumor model.

摘要

此前,已使用一种名为酸化学交换饱和转移磁共振成像(acidoCEST MRI)的分子成像技术对肿瘤组织和肾脏组织内的酸中毒进行了定量测量。先前的研究使用了碘普罗胺和碘帕醇,这两种碘化造影剂已被批准用于临床CT诊断,并被重新用于酸化学交换饱和转移磁共振成像研究。我们旨在通过优化图像采集条件、将pH值与造影剂的化学交换饱和转移(CEST)效应比值相关联以及评估浓度、内源性T1弛豫时间和温度对每种造影剂的pH-CEST比值相关性的影响,来比较这两种造影剂测量pH值的性能。这些结果表明,尽管碘普罗胺产生的pH测量值具有更高的动态范围,而碘帕醇产生的pH测量值更精确,但这两种造影剂具有相似的性能特征。然后,我们比较了这两种造影剂在Raji淋巴瘤和MCF-7乳腺癌异种移植肿瘤模型中测量体内细胞外pH值(pHe)的性能。我们的结果表明,用每种造影剂测量的pHe值没有显著差异。此外,在两种肿瘤模型中,相对于碘帕醇,碘普罗胺始终能测量到更大的肿瘤区域。因此,应根据特定生物医学研究所需的测量特性和特定肿瘤模型的药代动力学特性来选择用于酸化学交换饱和转移磁共振成像的碘化造影剂。

相似文献

引用本文的文献

本文引用的文献

10