Division of Balance Disorders, Department of Otorhinolaryngology and Head and Neck Surgery, Faculty of Health Medicine and Life Sciences, School for Mental Health and Neuroscience, Maastricht University Medical Center Maastricht, Netherlands ; Faculty of Physics, Tomsk State University Tomsk, Russia.

Service of Otorhinolaryngology and Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals Geneva, Switzerland.

出版信息

Front Syst Neurosci. 2015 Jan 20;8:255. doi: 10.3389/fnsys.2014.00255. eCollection 2014.

Abstract

The vestibulo-ocular reflex (VOR) shows frequency-dependent behavior. This study investigated whether the characteristics of the electrically evoked VOR (eVOR) elicited by a vestibular implant, showed the same frequency-dependency. Twelve vestibular electrodes implanted in seven patients with bilateral vestibular hypofunction (BVH) were tested. Stimuli consisted of amplitude-modulated electrical stimulation with a sinusoidal profile at frequencies of 0.5, 1, and 2 Hz. The main characteristics of the eVOR were evaluated and compared to the "natural" VOR characteristics measured in a group of age-matched healthy volunteers who were subjected to horizontal whole body rotations with equivalent sinusoidal velocity profiles at the same frequencies. A strong and significant effect of frequency was observed in the total peak eye velocity of the eVOR. This effect was similar to that observed in the "natural" VOR. Other characteristics of the (e)VOR (angle, habituation-index, and asymmetry) showed no significant frequency-dependent effect. In conclusion, this study demonstrates that, at least at the specific (limited) frequency range tested, responses elicited by a vestibular implant closely mimic the frequency-dependency of the "normal" vestibular system.

摘要

前庭眼反射(VOR)表现出频率依赖性。本研究旨在探讨前庭植入物诱发的电诱发前庭眼反射(eVOR)是否具有相同的频率依赖性。对 7 名双侧前庭功能低下(BVH)患者的 12 个前庭电极进行了测试。刺激采用正弦波轮廓的幅度调制电刺激,频率为 0.5、1 和 2 Hz。评估了 eVOR 的主要特征,并与一组年龄匹配的健康志愿者的“自然”VOR 特征进行了比较,这些志愿者在相同频率下进行了等效正弦速度轮廓的水平全身旋转。在 eVOR 的总峰值眼速度中观察到频率的强烈和显著影响。这种效应类似于在“自然”VOR 中观察到的效应。(e)VOR 的其他特征(角度、习惯指数和不对称性)没有表现出显著的频率依赖性。总之,本研究表明,至少在测试的特定(有限)频率范围内,前庭植入物诱发的反应与“正常”前庭系统的频率依赖性非常相似。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验