Suppr超能文献

两种金属陶瓷系统内部和边缘适合性的评估——体外研究。

Evaluation of internal and marginal fit of two metal ceramic system - in vitro study.

作者信息

V Harish, Ali S A Mohamed, N Jagadesan, Ifthikar Mohamed, Senthil Siva, Basak Debasish, Huda Febel

机构信息

Assistant Professor, Department of Prosthodontics, Srimuthukumaran Medical College , Chennai, India .

Assistant Professor, Department of Prosthodontics, Indira Gandhi institute of Dental Sciences , Pondicherry, India .

出版信息

J Clin Diagn Res. 2014 Dec;8(12):ZC53-6. doi: 10.7860/JCDR/2014/10372.5300. Epub 2014 Dec 5.

Abstract

INTRODUCTION

The high strength porcelain fused metal crowns have been extensively used in dentistry. However, the fit is the most encountered problems in porcelain fused metal crowns. This mainly depends on the fabrication technique.

AIM

The purpose was to compare the internal and marginal fit of laser sintered and conventionally casted Cobalt-Chromium copings.

MATERIALS AND METHODS

Twenty stainless steel dies of dimension 15 x 10 mm with 1 mm finish margin were fabricated using CAD-CAM technology. Twenty dies were divided into two groups Group 1 and Group 2 containing 10 samples each. All 20 dies were scanned using LAVA 3M scanner and data were used to fabricate metal copings using Laser sintering technique (Group-1) and Conventional casting technique (Group-2). Copings were cemented onto respective dies and finished and standardized sectioning were made. The sectioned models were scanned under stereomicroscope at 50 x magnification for internal and marginal fit evaluation.

RESULTS

Mean and standard deviation of internal and marginal discrepancy of laser sintered copings/conventional cast metal copings was 107.6 ± 10.9μ and 102.1 ± 17.2μ/187.09 ± 11.47 μ and 176.57 ± 25.82 μ respectively. Statistical analysis showed the laser sintered copings have lesser internal and marginal discrepancy than conventional casted copings with p value < 0.001.

CONCLUSION

The laser sintered Co-Cr copings showed better internal and marginal fit when compared to that of conventional Co-Cr casted copings.

摘要

引言

高强度烤瓷熔附金属冠在牙科领域已被广泛应用。然而,密合度是烤瓷熔附金属冠最常遇到的问题。这主要取决于制作技术。

目的

比较激光烧结和传统铸造的钴铬内冠的内部和边缘密合度。

材料与方法

使用CAD-CAM技术制作20个尺寸为15×10mm、边缘完成线为1mm的不锈钢代型。将20个代型分为两组,第1组和第2组,每组各含10个样本。使用LAVA 3M扫描仪对所有20个代型进行扫描,并将数据用于采用激光烧结技术(第1组)和传统铸造技术(第2组)制作金属内冠。将内冠粘固到各自的代型上,进行修整并制作标准化切片。在体视显微镜下以50倍放大率对切片模型进行扫描,以评估内部和边缘密合度。

结果

激光烧结内冠/传统铸造金属内冠的内部和边缘差异的平均值及标准差分别为107.6±10.9μm和102.1±17.2μm/187.09±11.47μm和176.57±25.82μm。统计分析表明,激光烧结内冠的内部和边缘差异小于传统铸造内冠,p值<0.001。

结论

与传统铸造的钴铬内冠相比,激光烧结的钴铬内冠显示出更好的内部和边缘密合度。

相似文献

1
Evaluation of internal and marginal fit of two metal ceramic system - in vitro study.
J Clin Diagn Res. 2014 Dec;8(12):ZC53-6. doi: 10.7860/JCDR/2014/10372.5300. Epub 2014 Dec 5.
2
Effect of production method on surface roughness, marginal and internal fit, and retention of cobalt-chromium single crowns.
J Prosthet Dent. 2017 Jul;118(1):95-101. doi: 10.1016/j.prosdent.2016.09.025. Epub 2016 Dec 23.
3
Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology.
J Prosthet Dent. 2015 Jun;113(6):623-7. doi: 10.1016/j.prosdent.2014.10.012. Epub 2015 Mar 18.
5
Marginal fit and microleakage of cast and metal laser sintered copings--an in vitro study.
J Prosthodont Res. 2014 Oct;58(4):252-8. doi: 10.1016/j.jpor.2014.07.002. Epub 2014 Aug 26.
6
Effect of finish line design and metal alloy on the marginal and internal gaps of selective laser melting printed copings.
J Prosthet Dent. 2019 Aug;122(2):143-151. doi: 10.1016/j.prosdent.2019.02.009. Epub 2019 Apr 1.
7
Fracture strength of porcelain fused to metal crowns made of cast, milled or laser-sintered cobalt-chromium.
Acta Odontol Scand. 2013 Sep;71(5):1280-9. doi: 10.3109/00016357.2012.757650. Epub 2013 Jan 16.
8
Evaluation of the fit of metal copings fabricated using stereolithography.
J Prosthet Dent. 2018 Nov;120(5):693-698. doi: 10.1016/j.prosdent.2018.01.012. Epub 2018 May 25.

引用本文的文献

1
Influence of various fabrication techniques and porcelain firing on the accuracy of metal-ceramic crowns.
BMC Oral Health. 2024 Jul 26;24(1):845. doi: 10.1186/s12903-024-04634-7.
3
Effect of repetitive firing on passive fit of metal substructure produced by the laser sintering in implant-supported fixed prosthesis.
J Adv Prosthodont. 2020 Jun;12(3):167-172. doi: 10.4047/jap.2020.12.3.167. Epub 2020 Jun 18.
4
A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses.
Biomater Investig Dent. 2020 Jan 20;7(1):31-40. doi: 10.1080/26415275.2020.1714445. eCollection 2020.
5
Comparison of Overall Fit of Milled and Laser-Sintered CAD/CAM Crown Copings.
Int J Dent. 2019 Jul 7;2019:7310175. doi: 10.1155/2019/7310175. eCollection 2019.
6
Comparison of marginal and internal adaptation of copings fabricated from three different fabrication techniques: An study.
J Indian Prosthodont Soc. 2018 Apr-Jun;18(2):102-107. doi: 10.4103/jips.jips_327_17.
7
Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis.
Biomed Res Int. 2018 Jan 23;2018:5049605. doi: 10.1155/2018/5049605. eCollection 2018.

本文引用的文献

2
Selective laser sintering in biomedical engineering.
Med Biol Eng Comput. 2013 Mar;51(3):245-56. doi: 10.1007/s11517-012-1001-x. Epub 2012 Dec 19.
6
Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain.
Dent Mater. 2008 Oct;24(10):1400-4. doi: 10.1016/j.dental.2008.03.001. Epub 2008 Apr 15.
7
Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology.
Dent Mater. 2008 Oct;24(10):1311-5. doi: 10.1016/j.dental.2008.02.011. Epub 2008 Apr 1.
8
Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology.
Dent Mater. 2008 Aug;24(8):1123-30. doi: 10.1016/j.dental.2008.01.008. Epub 2008 Mar 11.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验