Meigh R E, Makin T, Scott M H, Hart C A
University Department of Medical Microbiology, Royal Liverpool Hospital.
J Hosp Infect. 1989 Apr;13(3):315-9. doi: 10.1016/0195-6701(89)90013-3.
We describe the first reported case of pneumonia due to Legionella pneumophila serogroup 12 in the UK. This hospital-associated infection occurred in an immuno-incompetent patient and coincided with a change in character of the local environmental strains of legionellas. The patient produced a serological response both to her own isolate and to L. pneumophila serogroups 1-6. Thus serodiagnosis was attainable using the usual screening antigens.
我们描述了英国首例因嗜肺军团菌血清型12导致的肺炎报告病例。该医院相关感染发生在一名免疫功能不全的患者身上,并且与当地环境中军团菌菌株特性的变化同时出现。该患者对其自身分离株以及嗜肺军团菌血清型1 - 6均产生了血清学反应。因此,使用常规筛查抗原即可实现血清学诊断。