[用于尿培养的尿液样本自动划线系统的评估]

[Evaluation of an automated streaking system of urine samples for urine cultures].

作者信息

Bustamante Verónica, Meza Paulina, Román Juan C, García Patricia

出版信息

Rev Chilena Infectol. 2014 Dec;31(6):670-5. doi: 10.4067/S0716-10182014000600005.

Abstract

INTRODUCTION

Automated systems have simplified laboratory workflow, improved standardization, traceability and diminished human errors and workload. Although microbiology laboratories have little automation, in recent years new tools for automating pre analytical steps have appeared.

OBJECTIVES

To assess the performance of an automated streaking machine for urine cultures and its agreement with the conventional manual plating method for semi quantitative colony counts.

MATERIALS AND METHODS

495 urine samples for urinary culture were inoculated in CPS® agar using our standard protocol and the PREVI™ Isola. Rates of positivity, negativity, polymicrobial growth, bacterial species, colony counts and re-isolation requirements were compared.

RESULTS

Agreement was achieved in 98.97% of the positive/negative results, in 99.39% of the polymicrobial growth, 99.76% of bacterial species isolated and in 98.56 % of colony counts. The need for re-isolation of colonies decreased from 12.1% to 1.1% using the automated system.

DISCUSSION

PREVI™ Isola's performance was as expected, time saving and improving bacterial isolation. It represents a helpful tool for laboratory automation.

摘要

引言

自动化系统简化了实验室工作流程,提高了标准化、可追溯性,减少了人为误差和工作量。尽管微生物实验室的自动化程度较低,但近年来出现了用于自动化分析前步骤的新工具。

目的

评估一种用于尿液培养的自动划线机的性能及其与传统手动平板接种法在半定量菌落计数方面的一致性。

材料与方法

按照我们的标准方案,使用PREVI™ Isola在CPS®琼脂中接种495份用于尿液培养的尿液样本。比较阳性、阴性、多种微生物生长、细菌种类、菌落计数和重新分离要求的发生率。

结果

在98.97%的阳性/阴性结果、99.39%的多种微生物生长、99.76%的分离细菌种类和98.56%的菌落计数方面达成了一致。使用自动化系统,菌落重新分离的需求从12.1%降至1.1%。

讨论

PREVI™ Isola的性能符合预期,节省时间并改善了细菌分离。它是实验室自动化的一个有用工具。

相似文献

1
[Evaluation of an automated streaking system of urine samples for urine cultures].
Rev Chilena Infectol. 2014 Dec;31(6):670-5. doi: 10.4067/S0716-10182014000600005.
4
Automated urinalysis and urine dipstick in the emergency evaluation of young febrile children.
Pediatrics. 2014 Sep;134(3):523-9. doi: 10.1542/peds.2013-4222. Epub 2014 Aug 18.
5
Performance of Copan WASP for Routine Urine Microbiology.
J Clin Microbiol. 2016 Mar;54(3):585-92. doi: 10.1128/JCM.02577-15. Epub 2015 Dec 16.
8
[Evaluation of the performances of the UF-1000i(®) automated urine analyzer].
Ann Biol Clin (Paris). 2011 Jul-Aug;69(4):431-9. doi: 10.1684/abc.2011.0604.
9
New procedure to reduce the time and cost of broncho-pulmonary specimen management using the Previ Isola® automated inoculation system.
J Microbiol Methods. 2013 Dec;95(3):384-8. doi: 10.1016/j.mimet.2013.10.013. Epub 2013 Oct 29.
10
Transformation From a Conventional Clinical Microbiology Laboratory to Full Automation.
Lab Med. 2017 Dec 22;49(1):e1-e8. doi: 10.1093/labmed/lmx079.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验