Suppr超能文献

影响生产酪蛋白胶束浓缩物所需多级微滤过程膜面积的因素。

Factors that influence the membrane area of a multistage microfiltration process required to produce a micellar casein concentrate.

作者信息

Hurt Emily E, Barbano David M

机构信息

Northeast Dairy Foods Research Center, Department of Food Science, Cornell University, Ithaca, NY 14853.

Northeast Dairy Foods Research Center, Department of Food Science, Cornell University, Ithaca, NY 14853.

出版信息

J Dairy Sci. 2015 Apr;98(4):2222-33. doi: 10.3168/jds.2014-8880. Epub 2015 Feb 11.

Abstract

The objective of the work reported in this paper was to develop a theoretical model to determine the effect of type of microfiltration (MF)-process feed, number of stages, and flux on the minimization of the MF membrane area required to produce a 95% serum protein-reduced micellar casein concentrate. The MF feed, number of stages, and flux were all factors that had an effect on the MF membrane area and should be taken into consideration when designing a MF system to produce a 95% serum protein-reduced micellar casein concentrate. Feeding the MF process with a diluted ultrafiltration retentate (DUR) diluted to the protein concentration of skim milk, as opposed to skim milk, reduced the required membrane area by 36% for a 5-stage process. When DUR was the MF feed, feed protein concentration, which depended on the number of MF stages, was optimized. The DUR protein concentration that minimized the required MF membrane area was 2.47, 3.85, 4.77, and 5.41% for a 2-, 3-, 4-, or 5-stage MF process, respectively. For a 5-stage process, increasing the protein concentration of the feed from 3.2 to 5.4% decreased the required MF membrane area by 10%. It was also found that as the number of stages increased from 2 to 5, the required MF membrane area decreased by 39%, when the MF feed was DUR at the optimal feed protein concentration. Finally, increasing the flux from 50 to 60 kg/m(2) per hour decreased the required MF membrane area by 17% when the MF feed was DUR at the optimal MF feed protein concentration. Overall, using DUR as a feed for MF could reduce the amount of MF membrane area required to make a 95% serum protein-reduced micellar casein concentrate.

摘要

本文所报道工作的目的是建立一个理论模型,以确定微滤(MF)工艺进料类型、级数和通量对生产血清蛋白含量降低95%的胶束酪蛋白浓缩物所需最小化MF膜面积的影响。MF进料、级数和通量都是影响MF膜面积的因素,在设计生产血清蛋白含量降低95%的胶束酪蛋白浓缩物的MF系统时应予以考虑。与使用脱脂乳相比,用稀释至脱脂乳蛋白浓度的稀释超滤截留物(DUR)作为MF工艺的进料,对于五级工艺,所需膜面积减少了36%。当DUR作为MF进料时,取决于MF级数的进料蛋白浓度得到了优化。对于二级、三级、四级或五级MF工艺,使所需MF膜面积最小化的DUR蛋白浓度分别为2.47%、3.85%、4.77%和5.41%。对于五级工艺,将进料蛋白浓度从3.2%提高到5.4%,所需MF膜面积减少了10%。还发现,当MF进料为处于最佳进料蛋白浓度的DUR时,随着级数从2增加到5,所需MF膜面积减少了39%。最后,当MF进料为处于最佳MF进料蛋白浓度的DUR时,将通量从每小时50 kg/m²提高到60 kg/m²,所需MF膜面积减少了17%。总体而言,使用DUR作为MF的进料可以减少生产血清蛋白含量降低95%的胶束酪蛋白浓缩物所需的MF膜面积。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验