Kuntze Ferreira Alana Elisabeth, Neves Eduardo Borba
Federal Technological University of Paraná, Graduate Program in Biomedical Engineering, Curitiba, Brazil; Paraná Rehabilitation Center, Curitiba, Brazil.
Federal Technological University of Paraná, Graduate Program in Biomedical Engineering, Curitiba, Brazil.
Gait Posture. 2015 Feb;41(2):683-7. doi: 10.1016/j.gaitpost.2015.01.026. Epub 2015 Feb 4.
The purpose of this study was to compare gait deviations between Kondylen Bettung Münster (KBM) and vacuum prosthetic fitting using the Gait Profile Score (GPS), the Movement Analysis Profile (MAP) and temporal-spatial parameters. Seventeen transtibial amputees that received their prosthesis from the Brazilian governmental health system participated in this study. Twelve of them used KBM prosthetic fitting on their prosthesis and five used vacuum prosthetic fitting. Kinematic and temporal-spatial parameters data were captured by a six-camera Motion Analysis system (Santa Rosa, CA). The results showed that the vacuum group walked faster than the KBM group but the differences in temporal-spatial parameters between them were not significant. The GPS for the intact limb (IL) and the overall GPS differentiated between the groups of prosthetic fitting. Hip flexion/extension and knee flexion/extension were higher in KBM group than in the vacuum group, although only knee flexion/extension for the intact limb revealed significant difference between the groups. In KBM group, the major deviations were in hip flexion/extension for both limbs, knee flexion/extension for both limbs and ankle dorsi/plantar flexion for the prosthetic limb. The vacuum group showed deviations especially in ankle dorsi/plantar flexion for both limbs, knee flexion/extension for the prosthetic limb and hip rotation for the prosthetic limb. Besides, the vacuum group was more symmetrical than the KBM group. This study concluded that subjects who used vacuum prosthetic fitting presented smaller gait deviations and a more symmetrical gait than those who used KBM prosthetic fitting.
本研究的目的是使用步态轮廓评分(GPS)、运动分析轮廓(MAP)和时空参数,比较Kondylen Bettung Münster(KBM)与真空假肢适配之间的步态偏差。17名从巴西政府医疗系统获得假肢的经胫骨截肢者参与了本研究。其中12人在其假肢上使用KBM假肢适配,5人使用真空假肢适配。运动学和时空参数数据由六摄像头运动分析系统(加利福尼亚州圣罗莎)采集。结果表明,真空组比KBM组走得更快,但两组之间的时空参数差异不显著。完整肢体(IL)的GPS和总体GPS在假肢适配组之间存在差异。KBM组的髋关节屈伸和膝关节屈伸高于真空组,尽管仅完整肢体的膝关节屈伸在两组之间显示出显著差异。在KBM组中,主要偏差在于双下肢的髋关节屈伸、双下肢的膝关节屈伸以及假肢肢体的踝关节背屈/跖屈。真空组的偏差尤其体现在双下肢的踝关节背屈/跖屈、假肢肢体的膝关节屈伸以及假肢肢体的髋关节旋转。此外,真空组比KBM组更具对称性。本研究得出结论,与使用KBM假肢适配的受试者相比,使用真空假肢适配的受试者步态偏差更小,步态更具对称性。