Liao Xiaochun, Kemp Sandy, Corner George, Eisma Roos, Huang Zhihong
School of Engineering, Physics and Mathematics, University of Dundee, Dundee, DD1 4HN, United Kingdom.
Department of Medical Physics, Ninewells Hospital and Medical School, Dundee, DD1 9SY, United Kingdom.
Clin Anat. 2015 Oct;28(7):917-24. doi: 10.1002/ca.22512. Epub 2015 Feb 23.
Thiel embalming is recommended as an alternative to formalin-based embalming because it preserves tissue elasticity, color, and flexibility in the long term, with low infection and toxicity risk. The degree to which Thiel embalming preserves elasticity has so far been assessed mainly by subjective scoring, with little quantitative verification. The aim of this study is to quantify the effect of Thiel embalming on the elastic properties of human ankle tendons and ligament. Biomechanical tensile tests were carried out on six Thiel-embalmed samples each of the peroneus longus, peroneus brevis, and calcaneal tendons, and the calcaneofibular ligament, with strain rates of 0.25%s(-1), 2%s(-1), and 8%s(-1). The stress-strain relationship was calculated from the force-extension response with cross-sectional area and gauge length. Young's modulus was determined from the stress-strain curve. The results showed that the tendon and ligament elasticity were lower after Thiel embalming than the literature values for fresh nonembalmed tendons and ligament. The biomechanical tensile test showed that the measured elasticity of Thiel-embalmed tendons and ligaments increased with the strain rate. The Thiel embalming method is useful for preserving human ankle tendons and ligaments for anatomy and surgery teaching and research, but users need to be aware of its softening effects. The method retains the mechanical strain rate effect on tendons and ligament.
推荐使用蒂尔防腐法替代基于福尔马林的防腐法,因为它能长期保持组织弹性、颜色和柔韧性,感染和毒性风险较低。到目前为止,蒂尔防腐法对弹性的保存程度主要通过主观评分来评估,几乎没有定量验证。本研究的目的是量化蒂尔防腐法对人脚踝肌腱和韧带弹性特性的影响。对六份经蒂尔防腐处理的样本进行了生物力学拉伸试验,样本分别为腓骨长肌、腓骨短肌、跟腱以及跟腓韧带,应变率分别为0.25% s⁻¹、2% s⁻¹和8% s⁻¹。根据力 - 伸长响应以及横截面积和标距长度计算应力 - 应变关系。从应力 - 应变曲线确定杨氏模量。结果表明,经蒂尔防腐处理后的肌腱和韧带弹性低于新鲜未防腐处理的肌腱和韧带的文献值。生物力学拉伸试验表明,经蒂尔防腐处理的肌腱和韧带的测量弹性随应变率增加。蒂尔防腐法对于保存用于解剖学和外科学教学与研究的人脚踝肌腱和韧带很有用,但使用者需要注意其软化效果。该方法保留了对肌腱和韧带的机械应变率效应。