Suppr超能文献

灵敏的放射免疫分析(RIA)测定青春期前和青春期儿童的睾酮浓度,其结果与串联质谱法相当。

Sensitive RIA measures testosterone concentrations in prepubertal and pubertal children comparable to tandem mass spectrometry.

作者信息

Ankarberg-Lindgren Carina, Norjavaara Ensio

机构信息

Göteborg Pediatric Growth Research Center, Department of Pediatrics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg , S-41685 Göteborg , Sweden.

出版信息

Scand J Clin Lab Invest. 2015 Jul;75(4):341-4. doi: 10.3109/00365513.2014.942694. Epub 2015 Feb 27.

Abstract

BACKGROUND

Immunoassays have been criticized for poor accuracy at low testosterone concentrations. Mass spectrometry (MS) has been proposed as the only reliable method for testosterone determination. The aim of this study was to compare a sensitive testosterone radioimmunoassay (RIA) with results from different MS.

METHODS

We compared testosterone concentrations determined by a sensitive testosterone RIA, lower limit of detection 0.03 nmol/L and limit of quantitation 0.1 nmol/L, with four tandem MS that were included in an international external quality assessment program for laboratory medicine. We also compared the morning concentrations of testosterone in girls and boys at different pubertal stages, using results from the RIA, with reported values determined by LC-MS/MS, developed for androgen determination in children.

RESULTS

The mean (SD), concentrations were similar between RIA and MS: 1.5 (0.3) and 1.4 (0.4) in the child/women range (0.8-2.6 nmol/L) and 16.0 (3.7) and 17.8 (4.5) nmol/L for the adult male range (10.1-30.0 nmol/L), respectively. The ratio between RIA and MS versus results from mean values of the four MS methods was 1.0 (0.18); 1.1 (0.18) for child/women concentrations and 0.9 (0.13) for male testosterone concentrations. Furthermore, compared to the pediatric reference values determined by LC-MS/MS, the sensitive testosterone RIA delivered similar testosterone values across the different pubertal stages.

CONCLUSIONS

The comparison between different tandem MS methods and a sensitive testosterone RIA illustrates that there are immunoassays that deliver clinically useful information in prepubertal and pubertal children.

摘要

背景

免疫测定法因在低睾酮浓度下准确性欠佳而受到批评。质谱分析法(MS)已被提议作为测定睾酮的唯一可靠方法。本研究的目的是将一种灵敏的睾酮放射免疫测定法(RIA)与不同质谱分析法的结果进行比较。

方法

我们将灵敏的睾酮RIA(检测下限0.03 nmol/L,定量下限0.1 nmol/L)测定的睾酮浓度与纳入国际医学实验室外部质量评估计划的四种串联质谱分析法的结果进行比较。我们还使用RIA的结果,将不同青春期阶段女孩和男孩的晨间睾酮浓度与为儿童雄激素测定开发的液相色谱-串联质谱法(LC-MS/MS)测定的报告值进行比较。

结果

RIA和MS测定的平均(标准差)浓度相似:儿童/女性范围(0.8 - 2.6 nmol/L)分别为1.5(0.3)和1.4(0.4),成年男性范围(10.1 - 30.0 nmol/L)分别为16.0(3.7)和17.8(4.5)nmol/L。RIA和MS与四种MS方法平均值结果的比值为1.0(0.18);儿童/女性浓度为1.1(0.18),男性睾酮浓度为0.9(0.13)。此外,与LC-MS/MS测定的儿科参考值相比,灵敏的睾酮RIA在不同青春期阶段给出的睾酮值相似。

结论

不同串联质谱分析法与灵敏的睾酮RIA之间的比较表明,存在能为青春期前和青春期儿童提供临床有用信息的免疫测定法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验