与未骨化甲状腺软骨相比,鳞状细胞癌的不同光谱亨氏单位曲线及高能虚拟单色图像特征

Different spectral hounsfield unit curve and high-energy virtual monochromatic image characteristics of squamous cell carcinoma compared with nonossified thyroid cartilage.

作者信息

Forghani R, Levental M, Gupta R, Lam S, Dadfar N, Curtin H D

机构信息

From the Department of Radiology (R.F., M.L., S.L.), Jewish General Hospital, McGill University, Montreal, Quebec, Canada

From the Department of Radiology (R.F., M.L., S.L.), Jewish General Hospital, McGill University, Montreal, Quebec, Canada.

出版信息

AJNR Am J Neuroradiol. 2015 Jun;36(6):1194-200. doi: 10.3174/ajnr.A4253. Epub 2015 Mar 5.

Abstract

BACKGROUND AND PURPOSE

The attenuation of normal nonossified thyroid cartilage can be similar to that of head and neck squamous cell carcinoma on CT. We compared dual-energy CT spectral Hounsfield unit attenuation characteristics of nonossified thyroid cartilage with that of squamous cell carcinoma to determine the optimal virtual monochromatic image reconstruction energy levels for distinguishing tumor from normal nonossified thyroid cartilage.

MATERIALS AND METHODS

Dual-energy CT scans from 30 patients with histopathology-proved squamous cell carcinoma at different primary sites (laryngeal and nonlaryngeal) and 10 healthy patients were evaluated. Patients were scanned with a 64-section single-source scanner with fast-kilovolt (peak) switching, and scans were reconstructed at different virtual monochromatic energy levels ranging from 40 to 140 keV. Spectral attenuation curves of tumor and nonossified thyroid cartilage were quantitatively evaluated and compared. Any part of the tumor invading the cartilage, when present, was excluded from ROI analysis to avoid cross-contamination from areas where there could be a mixture of cartilage and invading tumor.

RESULTS

Normal nonossified thyroid cartilage had a characteristic, predictable spectral attenuation curve that was different from that of tumors. The greatest difference in attenuation of nonossified cartilage compared with tumor was on virtual monochromatic images of ≥95 keV (P < .0001), with sharp contrast between the relatively high attenuation of nonossified cartilage compared with that of tumor.

CONCLUSIONS

Head and neck squamous cell carcinoma has significantly different attenuation on virtual monochromatic images of ≥95 keV, compared with nonossified thyroid cartilage.

摘要

背景与目的

正常未骨化甲状腺软骨在CT上的衰减可能与头颈部鳞状细胞癌相似。我们比较了未骨化甲状腺软骨与鳞状细胞癌的双能CT光谱亨氏单位衰减特征,以确定区分肿瘤与正常未骨化甲状腺软骨的最佳虚拟单色图像重建能量水平。

材料与方法

对30例经组织病理学证实的不同原发部位(喉部和非喉部)鳞状细胞癌患者及10例健康患者的双能CT扫描进行评估。患者使用具有快速千伏(峰值)切换功能的64层单源扫描仪进行扫描,并在40至140keV的不同虚拟单色能量水平下进行图像重建。对肿瘤和未骨化甲状腺软骨的光谱衰减曲线进行定量评估和比较。肿瘤侵犯软骨的任何部分(若存在)均被排除在ROI分析之外,以避免来自软骨与侵袭性肿瘤混合区域的交叉污染。

结果

正常未骨化甲状腺软骨具有特征性、可预测的光谱衰减曲线,与肿瘤不同。未骨化软骨与肿瘤相比,衰减差异最大的是在≥95keV的虚拟单色图像上(P <.0001),未骨化软骨的相对高衰减与肿瘤之间形成鲜明对比。

结论

与未骨化甲状腺软骨相比,头颈部鳞状细胞癌在≥95keV的虚拟单色图像上具有显著不同的衰减。

相似文献

引用本文的文献

3
Dual-energy CT in head and neck applications.双能CT在头颈部的应用
Neuroradiol J. 2025 Jan 8:19714009251313507. doi: 10.1177/19714009251313507.
10
Clinical Applications of Dual-Energy CT.双能 CT 的临床应用。
Korean J Radiol. 2021 Jun;22(6):970-982. doi: 10.3348/kjr.2020.0996. Epub 2021 Apr 1.

本文引用的文献

7
Dual-energy CT applications in head and neck imaging.头部和颈部成像中的双能 CT 应用。
AJR Am J Roentgenol. 2012 Nov;199(5 Suppl):S34-9. doi: 10.2214/AJR.12.9113.
8
Dual-energy CT: general principles.双能 CT:一般原理。
AJR Am J Roentgenol. 2012 Nov;199(5 Suppl):S3-8. doi: 10.2214/AJR.12.9116.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验