Suppr超能文献

健康正常血压麻醉马匹不同解剖位置处有创血压与示波血压之间的等效性。

Equivalence between invasive and oscillometric blood pressures at different anatomic locations in healthy normotensive anaesthetised horses.

作者信息

Tearney C C, Guedes A G P, Brosnan R J

机构信息

Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California Davis, Davis, USA.

Department of Surgical and Radiological Sciences, University of California Davis, Davis, USA.

出版信息

Equine Vet J. 2016 May;48(3):357-61. doi: 10.1111/evj.12443. Epub 2015 May 23.

Abstract

REASONS FOR PERFORMING STUDY

Accurate blood pressure measurement is essential for effective clinical assessment and appropriate interventions in anaesthetised horses. Information on the accuracy of oscillometry for blood pressure measurement on the appendages of mature horses is limited.

OBJECTIVES

To assess equivalence between invasive and oscillometric blood pressures at different anatomic locations in horses.

STUDY DESIGN

Prospective experimental study using 6 healthy mature horses.

METHODS

Blood pressure was measured invasively in the right transverse facial artery and noninvasively by oscillometry in nondependent limbs and tail of laterally recumbent sevoflurane- or desflurane-anaesthetised horses. Cuff widths of 5-12 cm were tested on the tail, metatarsus, metacarpus and distal radius/ulna. Equivalence between mean arterial pressure (MAP) oscillometric and MAP invasive was assessed using a linear mixed effects model with a significance level of P≤0.05.

RESULTS

Twenty paired measurements were obtained for each cuff size in each of the locations, totalling 340 measurements. There was only one location (tail) and one cuff width (6 cm; cuff width-to-tail circumference ratio of 0.25) that resulted in equivalence between MAP measured with the oscillometric and the invasive methods (P = 0.8). All other locations (metacarpus, radius/ulna, metatarsus) and cuff widths were not equivalent (P≤0.01).

CONCLUSIONS

A cuff width-to-tail circumference ratio of 0.25 is recommended for accurate oscillometric blood pressure measurement in mature, laterally recumbent anaesthetised normotensive horses. Studies with variable haemodynamics are warranted. Oscillometric measurements at other extremities and/or with other cuff sizes cannot be recommended for clinical use.

摘要

开展本研究的原因

准确测量血压对于麻醉马匹的有效临床评估和适当干预至关重要。关于振荡法测量成年马附属肢体血压准确性的信息有限。

目的

评估马匹不同解剖位置处有创血压与振荡法血压之间的等效性。

研究设计

对6匹健康成年马进行前瞻性实验研究。

方法

在右侧面横动脉进行有创血压测量,并在侧卧的七氟烷或地氟烷麻醉马匹的非下垂肢体和尾部通过振荡法进行无创血压测量。对尾部、跖骨、掌骨和桡骨/尺骨远端测试了5 - 12厘米的袖带宽度。使用线性混合效应模型评估平均动脉压(MAP)振荡法测量值与有创测量值之间的等效性,显著性水平为P≤0.05。

结果

在每个位置针对每种袖带尺寸均获得了20对测量值,共计340次测量。只有一个位置(尾部)和一种袖带宽度(6厘米;袖带宽度与尾围之比为0.25)使得振荡法测量的MAP与有创法测量的MAP等效(P = 0.8)。所有其他位置(掌骨、桡骨/尺骨、跖骨)和袖带宽度均不等效(P≤0.01)。

结论

对于成年侧卧麻醉的血压正常马匹,建议使用袖带宽度与尾围之比为0.25来准确测量振荡法血压。有必要开展血流动力学变化的研究。不推荐在临床中使用其他肢体和/或其他袖带尺寸进行振荡法测量。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验