Chen Hua, Ma Shihua, Wu Xiumei, Yang Wenxing, Zhao Tian
J Biomed Opt. 2015 Mar;20(3):036017. doi: 10.1117/1.JBO.20.3.036017.
Based on a terahertz (THz) pipe-based near-field imaging system, we demonstrate the capability of THz imaging to diagnose freshly surgically excised human colonic tissues. Through THz near-field scanning the absorbance of the colonic tissues, the acquired images can clearly distinguish cancerous tissues from healthy tissues fast and automatically without pathological hematoxylin and eosin stain diagnosis. A statistical study on 58 specimens (20 healthy tissues and 38 tissues with tumor) from 31 patients (mean age: 59 years; range: 46 to 79 years) shows that the corresponding diagnostic sensitivity and specificity on colonic tissues are both 100%. Due to its capability to perform quantitative analysis, our study indicates the potential of the THz pipe-based near-field imaging for future automation on human tumor pathological examinations.
基于太赫兹(THz)管基近场成像系统,我们展示了太赫兹成像诊断新鲜手术切除的人类结肠组织的能力。通过太赫兹近场扫描结肠组织的吸光度,所获取的图像能够快速且自动地清晰区分癌组织与健康组织,无需病理苏木精和伊红染色诊断。对31名患者(平均年龄:59岁;范围:46至79岁)的58个标本(20个健康组织和38个肿瘤组织)进行的统计研究表明,对结肠组织的相应诊断敏感性和特异性均为100%。由于其具备进行定量分析的能力,我们的研究表明太赫兹管基近场成像在未来人类肿瘤病理检查自动化方面具有潜力。