Kam K Y Ronald, Ong Hon Shing, Bunce Catey, Ogunbowale Lola, Verma Seema
Moorfields Eye Hospital, London, UK Faculty of Medicine, Department of Surgery and Cancer, Imperial College London, London, UK.
Moorfields Eye Hospital, London, UK.
Br J Ophthalmol. 2015 Sep;99(9):1186-9. doi: 10.1136/bjophthalmol-2014-306508. Epub 2015 Mar 30.
To estimate the diagnostic accuracy (sensitivity and specificity) of the AdenoPlus point-of-care adenoviral test compared to PCR in an ophthalmic accident and emergency service. These findings were compared with those of a previous study.
This was a prospective diagnostic accuracy study on 121 patients presenting to an emergency eye unit with a clinical picture of acute adenoviral conjunctivitis. AdenoPlus testing was carried out on one eye of each patient and a PCR analysis was also performed on a swab taken from the same eye. AdenoPlus and PCR results were interpreted by masked personnel. Sensitivity and specificity for the AdenoPlus test were calculated using PCR results as the reference standard.
121 patients were enrolled and 109 met the inclusion criteria. 43 patients (39.4%) tested positive for adenovirus by PCR analysis. The sensitivity of the AdenoPlus swab in detecting adenovirus was 39.5% (17/43, 95% CI 26% to 54%) and specificity was 95.5% (63/66, 95% CI 87% to 98%) compared to PCR.
The AdenoPlus test has a high specificity for diagnosing adenoviral conjunctivitis, but in this clinical setting, we could not reproduce the high sensitivity that has been previously published.
评估在眼科急诊服务中,与聚合酶链反应(PCR)相比,AdenoPlus即时腺病毒检测的诊断准确性(敏感性和特异性)。将这些结果与之前一项研究的结果进行比较。
这是一项针对121名因急性腺病毒性结膜炎临床表现而就诊于眼科急诊单元的患者的前瞻性诊断准确性研究。对每位患者的一只眼睛进行AdenoPlus检测,并对取自同一只眼睛的拭子进行PCR分析。由不知情的人员解读AdenoPlus和PCR结果。以PCR结果作为参考标准计算AdenoPlus检测的敏感性和特异性。
共纳入121名患者,其中109名符合纳入标准。通过PCR分析,43名患者(39.4%)腺病毒检测呈阳性。与PCR相比,AdenoPlus拭子检测腺病毒的敏感性为39.5%(17/43,95%置信区间26%至54%),特异性为95.5%(63/66,95%置信区间87%至98%)。
AdenoPlus检测在诊断腺病毒性结膜炎方面具有较高的特异性,但在本临床环境中,我们无法重现之前发表的高敏感性。