Validity of activity monitors worn at multiple nontraditional locations under controlled and free-living conditions in young adult women.

作者信息

Kumahara Hideaki, Ayabe Makoto, Ichibakase Misato, Tashima Akari, Chiwata Maiko, Takashi Tomomi

机构信息

Faculty of Nutritional Sciences, Nakamura Gakuen University, 5-7-1 Befu, Jounan-ku, Fukuoka 814-0198, Japan.

出版信息

Appl Physiol Nutr Metab. 2015 May;40(5):448-56. doi: 10.1139/apnm-2014-0183. Epub 2015 Jan 12.

Abstract

The purpose of this study was to examine the validity of counting steps and computing indices of moderate-to-vigorous physical activity (MVPA) using miniature activity monitors with 3-D technology worn at various locations under controlled (CON) and free-living conditions (FL). Kenz e-style2, Tanita Calorism Smart, and Omron Calori Scan HJA-306 activity monitors were assessed. Nine and 31 young adult women were assigned to the CON and FL studies, respectively. While walking or jogging on a treadmill at 5 different speeds, the subjects simultaneously carried the 3 different monitors in a pants pocket (PP), a chest shirt pocket, and a shoulder bag (B). Under the FL condition, the 3 monitors were placed only at the PP and B locations for practical reasons. Significant effects of monitor location and walking/jogging speed on the step count measured by the 3 monitors were evaluated under the CON condition. Monitors placed at both PP and B tended to underestimate the number of steps; however, there were no significant differences between the values obtained with the Kenz monitor and those obtained with a criterion accelerometer under the FL condition. Moreover, strong correlations were observed between steps measured by monitors placed at PP and steps measured by the criterion accelerometer. The amount of MVPA for the PP location and the non-carrying duration of the bag for the B location were considered to be important determinants of the accuracy of step counting under the FL condition. In conclusion, monitors placed at the PP location, especially the Kenz monitor, showed acceptable accuracy for young adult women in real-life settings. In contrast, MVPA indices assessed using these monitors showed limited validity.

摘要

本研究的目的是在受控(CON)和自由生活条件(FL)下,使用佩戴在不同位置的具有三维技术的微型活动监测器,检验计算步数和计算中等到剧烈身体活动(MVPA)指数的有效性。对Kenz e-style2、Tanita Calorism Smart和欧姆龙Calori Scan HJA-306活动监测器进行了评估。分别有9名和31名年轻成年女性被分配到CON和FL研究中。在以5种不同速度在跑步机上行走或慢跑时,受试者同时将3种不同的监测器分别放在裤兜(PP)、胸袋和肩包(B)中。在FL条件下,出于实际原因,3种监测器仅放置在PP和B位置。在CON条件下,评估了监测器位置和行走/慢跑速度对3种监测器测量的步数的显著影响。放置在PP和B位置的监测器往往会低估步数;然而,在FL条件下,Kenz监测器获得的值与标准加速度计获得的值之间没有显著差异。此外,观察到放置在PP位置的监测器测量的步数与标准加速度计测量的步数之间存在很强的相关性。PP位置的MVPA量和B位置的包的未携带持续时间被认为是FL条件下步数计数准确性的重要决定因素。总之,放置在PP位置的监测器,尤其是Kenz监测器,在现实生活环境中对年轻成年女性显示出可接受的准确性。相比之下,使用这些监测器评估的MVPA指数显示出有限的有效性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验