Acoustic radiation force impulse elastography of the spleen in healthy dogs of different ages.

作者信息

Maronezi M C, Feliciano M A R, Crivellenti L Z, Simões A P R, Bartlewski P M, Gill I, Canola J C C, Vicente W R R

机构信息

Department of Surgery Veterinary, College of Agricultural and Veterinary Sciences, Sao Paulo State University (UNESP), Jaboticabal, Sao Paulo, Brazil.

Department of Animal Reproduction, College of Agricultural and Veterinary Sciences, Sao Paulo State University (UNESP), Jaboticabal, Sao Paulo, Brazil.

出版信息

J Small Anim Pract. 2015 Jun;56(6):393-7. doi: 10.1111/jsap.12349. Epub 2015 Mar 31.

Abstract

OBJECTIVES

To determine the elastographic characteristics of splenic parenchyma in clinically healthy dogs of various ages in order to establish preliminary qualitative and quantitative standards/reference intervals for this technique.

MATERIALS AND METHODS

Thirty three healthy dogs categorized as young, adult and elderly were used. Splenic echotexture, echogenicity, size and ages were assessed with B-mode ultrasonography. Using qualitative elastography, the spleen (head, body and tail) was examined for homogeneity and presence of deformities. Shear velocities in different splenic segments were then quantitatively evaluated.

RESULTS

All splenic segments visualised with the B-mode ultrasonography appeared normal. Different splenic segments examined with qualitative elastography were free of any detectable malformations and the images appeared as homogeneous dark areas. The mean shear velocity values were 2 · 32 m/s for head, 2 · 16 m/s for body and 2 · 25 m/s for tail of the spleen (P = 0 · 40), and they did not vary between the different age groups (P > 0 · 05).

CLINICAL SIGNIFICANCE

Quantitative and qualitative ARFI elastography of the spleen in clinically healthy dogs differing in age could be easily performed, and it may aid in the diagnosis and evaluation of splenic abnormalities routinely assessed in veterinary practice with B-mode ultrasonography.

摘要

目的

确定不同年龄临床健康犬脾脏实质的弹性成像特征,以便为该技术建立初步的定性和定量标准/参考区间。

材料与方法

使用33只分为幼年、成年和老年的健康犬。用B型超声评估脾脏的回声纹理、回声性、大小和年龄。采用定性弹性成像,检查脾脏(头、体和尾)的均匀性和有无畸形。然后定量评估脾脏不同节段的剪切波速度。

结果

B型超声显示的所有脾脏节段均正常。定性弹性成像检查的脾脏不同节段未发现任何可检测到的畸形,图像显示为均匀的暗区。脾脏头部的平均剪切波速度值为2·32米/秒,体部为2·16米/秒,尾部为2·25米/秒(P = 0·40),且在不同年龄组之间无差异(P > 0·05)。

临床意义

不同年龄临床健康犬的脾脏定量和定性ARFI弹性成像易于进行,可能有助于兽医临床实践中常规用B型超声评估的脾脏异常的诊断和评估。