Suppr超能文献

传统口腔根尖片与直接数字化根尖片在检测牙间骨丧失诊断准确性的比较。

Comparison of diagnostic accuracy of conventional intraoral periapical and direct digital radiographs in detecting interdental bone loss.

作者信息

Ashwinirani S R, Suragimath Girish, Jaishankar H P, Kulkarni Prasad, Bijjaragi Shobha C, Sangle Varsha Ajit

机构信息

Senior Lecturer, Department of Oral Medicine and Radiology, School of Dental Sciences , KIMSDU, Karad, Maharashtra, India .

Professor and HOD, Department of Periodontology, School of Dental Sciences , KIMSDU, Karad, Maharashtra, India .

出版信息

J Clin Diagn Res. 2015 Feb;9(2):ZC35-8. doi: 10.7860/JCDR/2015/12259.5562. Epub 2015 Feb 1.

Abstract

BACKGROUND

Periodontitis is an inflammatory disease of the supporting tissues of the teeth caused by specific microorganisms, resulting in destruction of the periodontal ligament and alveolar bone. Progressive loss of alveolar bone is the salient feature of periodontal disease. Accurate detection of periodontal disease with the use of radiographs helps in diagnosis, treatment and prognosis.

AIMS

The present study aims to compare the efficacy of conventional intraoral periapical (IOPA) and direct digital radiographs (RVG) in detecting interdental alveolar bone loss using intrasurgical (IS) measurements as the gold standard.

MATERIALS AND METHODS

Thirty patients elected to undergo periodontal flap surgery with periodontitis computing to 60 interdental alveolar defects on mandibular first molars were considered. IOPA and RVG were captured using standardized techniques. Bone loss measurements in IOPA and RVG were compared to the IS measurements.

STATISTICAL ANALYSIS

Statistical analysis was carried out using student t test and ANOVA with the help of SPSS software and p-value <0.05 was considered as significant.

RESULTS

Both IOPA and RVG underestimated the bone loss measurements when compared to IS measurements which was statistically significant (p<0.0001). Bone loss measurements in RVG were closer to IS measurements than IOPA.

CONCLUSION

Both the radiographic techniques IOPA and RVG underestimated bone loss by 1.5-2.5 mm. RVG was superior to IOPA for the detection of interdental bone loss due to reduced time and radiation exposure to obtain the same diagnostic information.

摘要

背景

牙周炎是由特定微生物引起的牙齿支持组织的炎症性疾病,导致牙周韧带和牙槽骨的破坏。牙槽骨的进行性丧失是牙周疾病的显著特征。使用X线片准确检测牙周疾病有助于诊断、治疗和预后评估。

目的

本研究旨在以手术中(IS)测量作为金标准,比较传统口腔内根尖片(IOPA)和直接数字化X线片(RVG)在检测牙间牙槽骨丧失方面的效果。

材料与方法

选取30例患有牙周炎并计划接受下颌第一磨牙牙周翻瓣手术的患者,共计60个牙间牙槽骨缺损。使用标准化技术拍摄IOPA和RVG。将IOPA和RVG中的骨丧失测量值与IS测量值进行比较。

统计分析

借助SPSS软件,使用学生t检验和方差分析进行统计分析,p值<0.05被视为具有统计学意义。

结果

与IS测量值相比,IOPA和RVG均低估了骨丧失测量值,差异具有统计学意义(p<0.0001)。RVG中的骨丧失测量值比IOPA更接近IS测量值。

结论

两种X线片技术IOPA和RVG均低估了骨丧失1.5 - 2.5毫米。由于获得相同诊断信息所需的时间和辐射暴露减少,RVG在检测牙间骨丧失方面优于IOPA。