Abstract

OBJECTIVE

To compare the accuracy and precision of measurements on marginal bone levels in differently processed digital radiographs and in film-based radiographs.

METHODS

Twenty-one patients with a diagnosis of chronic periodontitis were included in this study. Periapical radiographs were exposed with the Dixi digital intraoral radiographic system (Planmeca Oy, Helsinki, Finland) and the F-speed Film (Insight, Eastman-Kodak Co., Rochester, NY), respectively. Digital radiographs were subsequently processed into two sets: (a) correction for attenuation and visual response and (b) the same correction but with an additional shift in grey levels. Patients had periodontal surgery immediately after the radiographs were exposed. The vertical distance from cementoenamel junction to the most apical part of the marginal bone was assessed. The measurements were then employed as reference standard and subtracted by the vertical distance from radiographs accordingly. Altogether, 47 sites were evaluated. Seven observers were employed for evaluation under the same viewing conditions. ANOVA was employed for statistical analysis.

RESULTS

No significant differences were found between the absolute differences of the vertical distance obtained from radiographs to their corresponding reference standards when comparing differently processed digital radiographs, but the absolute differences were significantly smaller in digital radiographs than in films. Interobserver variances were not significant.

CONCLUSION

Digital radiographs have a favourable measurement accuracy compared with film radiographs when assessing marginal bone levels.

摘要

目的

比较不同处理方式的数字化X线片和传统胶片X线片中边缘骨水平测量的准确性和精确性。

方法

本研究纳入21例诊断为慢性牙周炎的患者。分别使用迪西数字化口腔内X线摄影系统(普兰梅卡公司,芬兰赫尔辛基)和F速胶片(伊士曼柯达公司,美国纽约罗切斯特)拍摄根尖片。随后将数字化X线片处理成两组:(a)进行衰减和视觉响应校正;(b)进行相同校正但灰度水平额外偏移。患者在拍摄X线片后立即接受牙周手术。评估从牙骨质釉质界到边缘骨最顶端部分的垂直距离。然后将测量结果作为参考标准,并相应地从X线片中减去垂直距离。总共评估了47个位点。七名观察者在相同观察条件下进行评估。采用方差分析进行统计分析。

结果

比较不同处理方式的数字化X线片时,从X线片获得的垂直距离与其相应参考标准之间的绝对差异无显著差异,但数字化X线片中的绝对差异明显小于胶片中的。观察者间差异不显著。

结论

在评估边缘骨水平时,与胶片X线片相比,数字化X线片具有良好的测量准确性。