Correcting for the thermodynamic characteristics of a body plethysmograph.

作者信息

Bates J H

机构信息

Meakins-Christie Laboratories, McGill University, Montreal, Quebec, Canada.

出版信息

Ann Biomed Eng. 1989;17(6):647-55. doi: 10.1007/BF02367468.

DOI:10.1007/BF02367468
PMID:2589696
Abstract

A constant volume body plethysmograph is used to measure changes in total body volume by relating pressure changes measured inside a closed chamber to changes in its volume. The relationship between pressure and volume, however, is complicated by the fact that rapid changes in pressure are accompanied by changes in the temperature of the gas in the plethysmograph. The rate at which the temperature of the gas subsequently approaches that of the environment affects the frequency response of the plethysmograph as a volume measuring instrument. In this paper it is shown that the transient response in plethysmograph pressure to a step change in volume must be a multi-component function, due to the gas near the walls of the plethysmograph approaching thermal equilibrium with the environment at a faster rate than gas near the center. The step response of a 200 L plethysmograph was determined experimentally and found to be well described empirically by a sum of two decaying exponential functions of time. The fitted exponentials were used to construct an algorithm for digitally correcting a measured pressure signal for the effects of the plethysmograph response. When applied to a hypothetical volume waveform over a single breath, an almost perfect correction was obtained.

摘要

相似文献

1
Correcting for the thermodynamic characteristics of a body plethysmograph.
Ann Biomed Eng. 1989;17(6):647-55. doi: 10.1007/BF02367468.
2
Effect of the thermodynamics of an infant plethysmograph on the measurement of thoracic gas volume.
Pediatr Pulmonol. 1990;8(3):203-8. doi: 10.1002/ppul.1950080312.
3
Unrestrained acoustic plethysmograph for measuring tidal volume in mice.
Ann Biomed Eng. 2006 Sep;34(9):1494-9. doi: 10.1007/s10439-006-9159-8. Epub 2006 Aug 1.
4
[Aerodynamics study on pressure changes inside pressure-type whole-body plethysmograph produced by flowing air].[气流作用下压力型全身体积描记器内部压力变化的空气动力学研究]
Sheng Li Xue Bao. 2010 Feb 25;62(1):42-8.
5
Volume-displacement body plethysmograph using a large flowmeter without pressure compensation.使用无压力补偿的大型流量计的容积置换式人体体积描记器。
J Appl Physiol Respir Environ Exerc Physiol. 1979 Nov;47(5):1127-30. doi: 10.1152/jappl.1979.47.5.1127.
6
Hyperbaric whole-body plethysmograph for rodents.
Undersea Biomed Res. 1983 Jun;10(2):135-45.
7
Thermal behavior of the constant volume body plethysmograph.定容式人体体积描记器的热行为。
IEEE Trans Biomed Eng. 1995 Mar;42(3):269-77. doi: 10.1109/10.364513.
8
Correction for nonlinearity of body flow plethysmograph.人体血流体积描记仪非线性的校正。
J Appl Physiol Respir Environ Exerc Physiol. 1981 Mar;50(3):658-62. doi: 10.1152/jappl.1981.50.3.658.
9
PC processor for plethysmograph airway resistance and thoracic gas volume measurement.用于体积描记法气道阻力和胸腔气体容积测量的PC处理器。
Med Biol Eng Comput. 1994 May;32(3):342-8. doi: 10.1007/BF02512535.
10
[Effects of mice body temperature on pressure inside plethysmograph].[小鼠体温对体积描记器内压力的影响]
Zhejiang Da Xue Xue Bao Yi Xue Ban. 2011 May;40(3):315-20. doi: 10.3785/j.issn.1008-9292.2011.03.015.