Suppr超能文献

一种新型热塑性可滴定下颌前移装置的体外固位

In vitro retention of a new thermoplastic titratable mandibular advancement device.

作者信息

Braem Marc

机构信息

Lab Dental Materials, University of Antwerp, Antwerp, 2610, Belgium ; Special Care Dentistry, University Hospital Antwerp, Edegem, 2650, Belgium ; Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, 2610, Belgium.

出版信息

F1000Res. 2015 Feb 26;4:56. doi: 10.12688/f1000research.6061.1. eCollection 2015.

Abstract

Oral appliance (OA) therapy with a mandibular advancement device (OAm) is a non-invasive, alternative approach to maintaining upper airway patency. The main requirement for an OAm to be effective is the adequate retention on the teeth while the patient is asleep. We evaluated the retentive forces of a new low-cost, customizable, titratable, thermoplastic OAm (BluePro (®); BlueSom, France). Dental impressions and casts were made for one patient with complete upper and lower dental arches including the third molars and class II bite proportions. A setup based on Frasaco ANA-4 models was also used. Two protrusive positions of the mandible were investigated: 3 mm and 8 mm, representing respectively 25% and 65% of the maximal protrusion. The forces required to remove the BluePro (®) device from the carriers were recorded continuously over 730 cycles (=365 days, twice a day) to simulate 1 year of clinical use. At 8 mm protrusion the BluePro (®) device showed retentive forces of ~27N. There was a slight but non-significant decrease in retentive forces in the tests on the epoxified carriers which was not found on the ANA-4 carriers. There were no significant differences between the carriers as a function of protrusion. The BluePro (®) device tested in the present study possesses sufficient retention forces to resist initial jaw opening forces and full mouth opening forces estimated to be ~20N. It could therefore broaden the indications for use of thermoplastic OAms. It could provide a temporary OAm while a custom-made OAm is being manufactured or repaired. Patients could be provided with a low-cost try-out device capable of reliable titration, providing an indication of effectiveness and of patient acceptance of an OAm, although the effect of device shape and size on therapeutic outcome is not yet known. Finally it could provide an affordable OAm solution in resource-restricted healthcare settings.

摘要

使用下颌前移装置(OAm)的口腔矫治器(OA)疗法是一种维持上呼吸道通畅的非侵入性替代方法。OAm有效的主要要求是患者睡眠时其在牙齿上有足够的固位力。我们评估了一种新型低成本、可定制、可滴定的热塑性OAm(BluePro(®);法国BlueSom公司)的固位力。为一名上下牙弓完整包括第三磨牙且为II类咬合比例的患者制取了牙印模和石膏模型。还使用了基于Frasaco ANA - 4模型的装置。研究了下颌的两个前伸位置:3毫米和8毫米,分别代表最大前伸的25%和65%。在730个循环(=365天,每天两次)中持续记录将BluePro(®)装置从载体上取下所需的力,以模拟1年的临床使用。在8毫米前伸时,BluePro(®)装置显示出约27N的固位力。在环氧载体上的测试中固位力有轻微但不显著的下降,而在ANA - 4载体上未发现这种情况。作为前伸函数,载体之间没有显著差异。本研究中测试的BluePro(®)装置具有足够的固位力来抵抗估计约为20N的初始张口力和全口张开力。因此,它可以扩大热塑性OAm的使用适应症。在定制的OAm制造或修复期间,它可以提供一个临时的OAm。可以为患者提供一种能够可靠滴定的低成本试用装置,提供OAm有效性和患者接受度的指标,尽管装置形状和尺寸对治疗结果的影响尚不清楚。最后,它可以在资源有限的医疗环境中提供一种经济实惠的OAm解决方案。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0ea3/4392831/2c6f20a60f79/f1000research-4-6489-g0000.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验