Paravalvular leak is a significant complication after surgical valve replacement. Traditionally, redo surgery has been considered the treatment of choice, but is associated with high morbidity and mortality as well as increase risk of developing new leaks. Percutaneous treatment of paravalvular leak appears as an attractive alternative. Such treatment has been made possible by the current ability to integrate multiple imaging modalities that have helped to define the anatomy of the defect and planning and guiding the percutaneous closure procedure, thus resulting in better outcomes. The Amplatzer® Vascular Plug III (St. Jude Medical) is the first device specifically designed for percutaneous closure of paravalvular leak with promising results. We present the three-dimensional transesophageal echocardiographic images of a successful outcome of percutaneous closure of a residual mitral paravalvular leak with an Amplatzer® Vascular Plug III device (St. Jude Medical), after an initial procedure of percutaneous closure with an Amplatzer® duct occluder (St. Jude Medical).

摘要

瓣周漏是外科瓣膜置换术后的一种严重并发症。传统上,再次手术一直被视为首选治疗方法,但它与高发病率、高死亡率以及出现新漏口的风险增加相关。经皮治疗瓣周漏似乎是一种有吸引力的替代方法。目前能够整合多种成像模式,这有助于明确缺损的解剖结构以及规划和引导经皮封堵手术,从而使这种治疗成为可能,进而带来更好的治疗效果。Amplatzer®血管封堵器III型(圣犹达医疗公司)是首个专门设计用于经皮封堵瓣周漏的器械,取得了令人满意的效果。我们展示了在最初使用Amplatzer®动脉导管封堵器(圣犹达医疗公司)进行经皮封堵后,使用Amplatzer®血管封堵器III型(圣犹达医疗公司)成功经皮封堵残余二尖瓣瓣周漏的三维经食管超声心动图图像。