Suppr超能文献

抗凝血液标本中检测假性溶血的评分系统。

Scoring system for detecting spurious hemolysis in anticoagulated blood specimens.

作者信息

Yoo Gilsung, Kim Juwon, Uh Young, Yoon Kwang Ro, Park Soon Deok, Yoon Kap Jun

机构信息

Department of Laboratory Medicine, Yonsei University Wonju College of Medicine, Wonju, Korea.

出版信息

Ann Lab Med. 2015 May;35(3):341-7. doi: 10.3343/alm.2015.35.3.341. Epub 2015 Apr 1.

Abstract

BACKGROUND

The identification of in vitro hemolysis (IVH) using a hematology analyzer is challenging because centrifugation of the specimens cannot be performed for cell counts. In the present study, we aimed to develop a scoring system to help identify the presence of hemolysis in anticoagulated blood specimens.

METHODS

Thirty-seven potassium EDTA anticoagulated blood specimens were obtained, and each specimen was divided into 3 aliquots (A, B, and C). Aliquots B and C were mechanically hemolyzed by aspirating 2 and 5 times, respectively, using a 27-gauge needle and then tested; aliquot A was analyzed immediately without any hemolysis. After the cells were counted, aliquots B and C were centrifuged and the supernatants were tested for the hemolytic index and lactate dehydrogenase levels.

RESULTS

The 4 hematologic parameters were selected and scored from 0 to 3 as follows:< 34.0, 34.0-36.2, 36.3-38.4, and ≥38.5 for mean cell hemoglobin concentration (MCHC, g/dL); <0.02, 0.02, 0.03, and ≥0.04 for red blood cell ghosts (10(12)/L); <0.13, 0.13-0.38, 0.39-1.30, and ≥1.31 for difference value (g/dL) of measured hemoglobin and calculated hemoglobin; and <0.26, 0.26-0.95, 0.96-3.34, and ≥3.35 for difference value (g/dL) of MCHC and cell hemoglobin concentration mean. The hemolysis score was calculated by adding all the scores from the 4 parameters. At the cutoff hemolysis score of 3, the IVH of aliquots B and C were detected as 64.9% and 91.9%, respectively.

CONCLUSIONS

The scoring system might provide effective screening for detecting spurious IVH.

摘要

背景

使用血液分析仪识别体外溶血(IVH)具有挑战性,因为无法对标本进行离心以进行细胞计数。在本研究中,我们旨在开发一种评分系统,以帮助识别抗凝血液标本中溶血的存在。

方法

获取37份乙二胺四乙酸钾抗凝血液标本,每份标本分为3份(A、B和C)。分别使用27号针头抽吸2次和5次,对B份和C份进行机械溶血,然后进行检测;A份不进行任何溶血处理,立即进行分析。细胞计数后,对B份和C份进行离心,并检测上清液的溶血指数和乳酸脱氢酶水平。

结果

选择4项血液学参数并按0至3分进行评分,具体如下:平均红细胞血红蛋白浓度(MCHC,g/dL):<34.0、34.0 - 36.2、36.3 - 38.4、≥38.5;红细胞影(10¹²/L):<0.02、0.02、0.03、≥0.04;实测血红蛋白与计算血红蛋白差值(g/dL):<0.13、0.13 - 0.38、0.39 - 1.30、≥1.31;MCHC与细胞血红蛋白浓度均值差值(g/dL):<0.26、0.26 - 0.95、0.96 - 3.34、≥3.35。溶血评分通过将这4项参数的所有分数相加得出。在溶血评分临界值为3时,B份和C份的IVH检测率分别为64.9%和91.9%。

结论

该评分系统可能为检测假性IVH提供有效的筛查方法。

相似文献

1
Scoring system for detecting spurious hemolysis in anticoagulated blood specimens.
Ann Lab Med. 2015 May;35(3):341-7. doi: 10.3343/alm.2015.35.3.341. Epub 2015 Apr 1.
3
Influence of mechanical hemolysis of blood on two D-dimer immunoassays.
Blood Coagul Fibrinolysis. 2012 Jul;23(5):461-3. doi: 10.1097/MBC.0b013e3283549696.
4
Influence of in vitro hemolysis on hematological testing on Advia 2120.
Int J Lab Hematol. 2012 Apr;34(2):179-84. doi: 10.1111/j.1751-553X.2011.01378.x. Epub 2011 Nov 3.
6
Influence of spurious hemolysis on blood gas analysis.
Clin Chem Lab Med. 2013 Aug;51(8):1651-4. doi: 10.1515/cclm-2012-0802.
7
Influence of mechanical trauma of blood and hemolysis on PFA-100 testing.
Blood Coagul Fibrinolysis. 2012 Jan;23(1):82-6. doi: 10.1097/MBC.0b013e32834c6cb5.
8
Influence of in vitro hemolysis on nucleated red blood cells and reticulocyte counts.
Int J Lab Hematol. 2013 Apr;35(2):225-8. doi: 10.1111/ijlh.12012. Epub 2012 Oct 4.
10
Development of simple equations for effective screening of spurious hemolysis in whole-blood specimens.
Int J Lab Hematol. 2015 Apr;37(2):253-8. doi: 10.1111/ijlh.12277. Epub 2014 Jul 12.

引用本文的文献

1
Optimizing the management of analytical interferences affecting red blood cells on XN-10 (Sysmex®).
Int J Lab Hematol. 2022 Dec;44(6):1068-1077. doi: 10.1111/ijlh.13951. Epub 2022 Aug 22.
2
ACVIM consensus statement on the diagnosis of immune-mediated hemolytic anemia in dogs and cats.
J Vet Intern Med. 2019 Mar;33(2):313-334. doi: 10.1111/jvim.15441. Epub 2019 Feb 26.

本文引用的文献

1
Development of an integrated reporting system for verifying hemolysis, icterus, and lipemia in clinical chemistry results.
Ann Lab Med. 2014 Jul;34(4):307-12. doi: 10.3343/alm.2014.34.4.307. Epub 2014 Jun 19.
3
Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories.
Crit Rev Clin Lab Sci. 2011 May-Jun;48(3):143-53. doi: 10.3109/10408363.2011.600228.
4
Automated quantitation of hemoglobin-based blood substitutes in whole blood samples.
Am J Clin Pathol. 2001 Dec;116(6):913-9. doi: 10.1309/38LC-5K57-MBFX-VX6D.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验