Suppr超能文献

体外溶血对 Advia 2120 血液学检测的影响。

Influence of in vitro hemolysis on hematological testing on Advia 2120.

机构信息

U.O. Diagnostica Ematochimica, Dipartimento di Patologia e Medicina di Laboratorio, Azienda Ospedaliero-Universitaria di Parma, Italy.

出版信息

Int J Lab Hematol. 2012 Apr;34(2):179-84. doi: 10.1111/j.1751-553X.2011.01378.x. Epub 2011 Nov 3.

Abstract

INTRODUCTION

Although there is broad knowledge on the effect of several preanalytical errors on laboratory hematology, there is no information on the reliability of routine hematological testing on hemolyzed specimens.

METHODS

K(2) EDTA-anticoagulated blood collected from 13 healthy volunteers was divided in three aliquots. Aliquot A did not undergo further manipulation, while the second and third aliquots (B and C, respectively) were passed 5 and 10 times through a small-gauge needle to produce scalar amounts of hemolysis. Hematological testing was first performed on Advia 2120. The plasma was then separated by centrifugation and tested for lactate dehydrogenase and hemolysis index (HI).

RESULTS

As compared with the nonhemolyzed aliquot, analytically and clinically significant variations were recorded in both mildly and frankly hemolyzed specimens for lactate dehydrogenase, HI, red blood cells count, hematocrit, mean corpuscular volume, mean hemoglobin content, lymphocytes, basophils, and large unstained cells. Both the platelets count and the mean platelet volume were also dramatically affected. The other parameters tested (hemoglobin, red blood cell distribution width, neutrophils, and eosinophils) did not vary significantly.

CONCLUSION

The results of routine hematological testing on mildly to frankly hemolyzed specimens might be unreliable.

摘要

简介

尽管有广泛的知识了解几种分析前误差对实验室血液学的影响,但关于溶血标本常规血液学检测的可靠性尚无信息。

方法

从 13 名健康志愿者采集的 K(2) EDTA 抗凝血液分为三份。标本 A 未进行进一步处理,而第二和第三份标本(B 和 C)分别通过小口径针头通过 5 次和 10 次以产生轻微的溶血程度。首先在 Advia 2120 上进行血液学检测。然后通过离心分离血浆,并检测乳酸脱氢酶和溶血指数(HI)。

结果

与非溶血标本相比,在轻度和明显溶血标本中,乳酸脱氢酶、HI、红细胞计数、血细胞比容、平均红细胞体积、平均血红蛋白含量、淋巴细胞、嗜碱性粒细胞和大未染色细胞的分析和临床显著变化均有记录。血小板计数和血小板平均体积也受到显著影响。其他测试的参数(血红蛋白、红细胞分布宽度、中性粒细胞和嗜酸性粒细胞)没有显著变化。

结论

轻度至明显溶血标本的常规血液学检测结果可能不可靠。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验