Sridharan Anush, Eisenbrey John R, Machado Priscilla, Ojeda-Fournier Haydee, Wilkes Annina, Sevrukov Alexander, Mattrey Robert F, Wallace Kirk, Chalek Carl L, Thomenius Kai E, Forsberg Flemming
IEEE Trans Ultrason Ferroelectr Freq Control. 2015 Mar;62(3):502-10. doi: 10.1109/tuffc.2014.006886.
Ability to visualize breast lesion vascularity and quantify the vascular heterogeneity using contrast-enhanced 3-D harmonic (HI) and subharmonic (SHI) ultrasound imaging was investigated in a clinical population. Patients (n = 134) identified with breast lesions on mammography were scanned using power Doppler imaging, contrast-enhanced 3-D HI, and 3-D SHI on a modified Logiq 9 scanner (GE Healthcare). A region of interest corresponding to ultrasound contrast agent flow was identified in 4D View (GE Medical Systems) and mapped to raw slice data to generate a map of time-intensity curves for the lesion volume. Time points corresponding to baseline, peak intensity, and washout of ultrasound contrast agent were identified and used to generate and compare vascular heterogeneity plots for malignant and benign lesions. Vascularity was observed with power Doppler imaging in 84 lesions (63 benign and 21 malignant). The 3-D HI showed flow in 8 lesions (5 benign and 3 malignant), whereas 3-D SHI visualized flow in 68 lesions (49 benign and 19 malignant). Analysis of vascular heterogeneity in the 3-D SHI volumes found benign lesions having a significant difference in vascularity between central and peripheral sections (1.71 ± 0.96 vs. 1.13 ± 0.79 dB, p < 0.001, respectively), whereas malignant lesions showed no difference (1.66 ± 1.39 vs. 1.24 ± 1.14 dB, p = 0.24), indicative of more vascular coverage. These preliminary results suggest quantitative evaluation of vascular heterogeneity in breast lesions using contrast-enhanced 3-D SHI is feasible and able to detect variations in vascularity between central and peripheral sections for benign and malignant lesions.
在临床人群中研究了使用对比增强三维谐波(HI)和次谐波(SHI)超声成像来可视化乳腺病变血管并量化血管异质性的能力。对在乳腺X线摄影中发现有乳腺病变的患者(n = 134),在改良的Logiq 9扫描仪(GE医疗保健公司)上使用能量多普勒成像、对比增强三维HI和三维SHI进行扫描。在4D视图(GE医疗系统)中识别出与超声造影剂流动相对应的感兴趣区域,并将其映射到原始切片数据,以生成病变体积的时间-强度曲线图谱。确定与超声造影剂的基线、峰值强度和洗脱相对应的时间点,并用于生成和比较恶性和良性病变的血管异质性图。在84个病变(63个良性和21个恶性)中通过能量多普勒成像观察到血管情况。三维HI显示8个病变中有血流(5个良性和3个恶性),而三维SHI显示68个病变中有血流(49个良性和19个恶性)。对三维SHI体积中的血管异质性分析发现,良性病变在中央和外周部分的血管情况有显著差异(分别为1.71±0.96与1.13±0.79 dB,p<0.001),而恶性病变无差异(1.66±1.39与1.24±1.14 dB,p = 0.24),表明血管覆盖更多。这些初步结果表明,使用对比增强三维SHI对乳腺病变的血管异质性进行定量评估是可行的,并且能够检测出良性和恶性病变在中央和外周部分血管情况的差异。