一种用于非小细胞肺癌电视辅助胸腔镜手术前哨淋巴结定位的新型磁力计的研发

Development of a New Magnetometer for Sentinel Lymph Node Mapping Designed for Video-Assisted Thoracic Surgery in Non-Small Cell Lung Cancer.

作者信息

Imai Kazuhiro, Kawaharada Yasushi, Ogawa Jun-Ichi, Saito Hajime, Kudo Satoshi, Takashima Shinogu, Saito Yoshitaro, Atari Maiko, Ito Aki, Terata Kaori, Yoshino Kei, Sato Yusuke, Motoyama Satoru, Minamiya Yoshihiro

机构信息

Akita University Graduate School of Medicine, Akita, Japan

Akita University Graduate School of Medicine, Akita, Japan.

出版信息

Surg Innov. 2015 Aug;22(4):401-5. doi: 10.1177/1553350615585421. Epub 2015 May 4.

Abstract

BACKGROUND

We previously developed a method for sentinel lymph node (SLN) mapping in non-small cell lung cancer (NSCLC), based on the magnetic force produced by a magnetite tracer already approved for use as a contrast material for magnetic resonance imaging. However, it is difficult to use that technique with video-assisted thoracic surgery (VATS) because the sensing element of the magnetometer is large and thick. The purpose of the present study was to develop a smaller, thinner VATS-compatible magnetometer.

METHODS

The tracer employed was Ferucarbotran, a colloidal solution of superparamagnetic iron oxide coated with carbodextran. Fifteen patients with clinical stage I NSCLC were enrolled, and each received 1.6 mL of Ferucarbotran, injected intraoperatively at 5 points around the tumor. The magnetic force within the sampling lymph nodes was measured using the new VATS-compatible magnetometer.

RESULTS

SLNs were detected in 11 (73.3%) of the 15 patients using the VATS-compatible magnetometer. The average number of SLNs identified per patient was 1.8 (range 0-4). No complications related to the SLN detection method were observed.

CONCLUSIONS

The new VATS-compatible magnetometer appears to have substantial advantages over techniques using a radioisotope and our earlier magnetometer, as it can be inserted through the small VATS port site.

摘要

背景

我们之前开发了一种用于非小细胞肺癌(NSCLC)前哨淋巴结(SLN)定位的方法,该方法基于一种已被批准用作磁共振成像造影剂的磁铁矿示踪剂产生的磁力。然而,由于磁力计的传感元件大且厚,很难将该技术用于电视辅助胸腔镜手术(VATS)。本研究的目的是开发一种更小、更薄且适用于VATS的磁力计。

方法

所使用的示踪剂是Ferucarbotran,一种用碳糊精包裹的超顺磁性氧化铁胶体溶液。纳入15例临床I期NSCLC患者,每例患者术中在肿瘤周围5个点注射1.6 mL Ferucarbotran。使用新型适用于VATS的磁力计测量采样淋巴结内的磁力。

结果

使用适用于VATS的磁力计在15例患者中的11例(73.3%)检测到了前哨淋巴结。每位患者识别出的前哨淋巴结平均数量为1.8个(范围0 - 4个)。未观察到与前哨淋巴结检测方法相关的并发症。

结论

新型适用于VATS的磁力计似乎比使用放射性同位素的技术和我们早期的磁力计具有显著优势,因为它可以通过VATS的小切口插入。