Guo Chuan-Guo, Ji Rui, Li Yan-Qing
Department of Gastroenterology, Qilu Hospital, Shandong University, Jinan, Shandong Province, China.
PLoS One. 2015 May 15;10(5):e0126237. doi: 10.1371/journal.pone.0126237. eCollection 2015.
i-Scan is a novel virtual chromoendoscopy system designed to enhance surface and vascular patterns to improve optical diagnostic performance. Numerous prospective studies have been done to evaluate the accuracy of i-Scan in differentiating colonic neoplasms from non-neoplasms. i-Scan could be an effective endoscopic technique for optical diagnosis of colonic polyps.
Our aim of this study was to perform a meta-analysis of published data to establish the diagnostic accuracy of i-Scan for optical diagnosis of colonic polyps.
We searched PubMed, Medline, Elsevier ScienceDirect and Cochrane Library databases. We used a bivariate meta-analysis following a random effects model to summarize the data and plotted hierarchical summary receiver-operating characteristic (HSROC) curves. The area under the HSROC curve (AUC) serves as an indicator of the diagnostic accuracy.
The meta-analysis included a total of 925 patients and 2312 polyps. For the overall studies, the area under the HSROC curve was 0.96. The summary sensitivity was 90.4% (95%CI 85%-94.1%) and specificity was 90.9% (95%CI 84.3%-94.9%). In 11 studies predicting polyps histology in real-time, the summary sensitivity and specificity was 91.5% (95%CI 85.7%-95.1%) and 92.1% (95%CI 84.5%-96.1%), respectively, with the AUC of 0.97. For three different diagnostic criteria (Kudo, NICE, others), the sensitivity was 86.3%, 93.0%, 85.0%, respectively and specificity was 84.8%, 94.4%, 91.8%, respectively.
Endoscopic diagnosis with i-Scan has accurate optical diagnostic performance to differentiate neoplastic from non-neoplastic polyps with an area under the HSROC curve exceeding 0.90. Both the sensitivity and specificity for diagnosing colonic polyps are over 90%.
i-Scan是一种新型的虚拟染色内镜系统,旨在增强表面和血管形态,以提高光学诊断性能。已经进行了大量前瞻性研究来评估i-Scan在区分结肠肿瘤与非肿瘤方面的准确性。i-Scan可能是一种用于光学诊断结肠息肉的有效内镜技术。
本研究的目的是对已发表的数据进行荟萃分析,以确定i-Scan用于光学诊断结肠息肉的诊断准确性。
我们检索了PubMed、Medline、爱思唯尔ScienceDirect和考克兰图书馆数据库。我们采用随机效应模型下的双变量荟萃分析来汇总数据,并绘制分层汇总接受者操作特征(HSROC)曲线。HSROC曲线下面积(AUC)作为诊断准确性的指标。
荟萃分析共纳入925例患者和2312个息肉。对于总体研究,HSROC曲线下面积为0.96。汇总敏感性为90.4%(95%CI 85%-94.1%),特异性为90.9%(95%CI 84.3%-94.9%)。在11项实时预测息肉组织学的研究中,汇总敏感性和特异性分别为91.5%(95%CI 85.7%-95.1%)和92.1%(95%CI 84.5%-96.1%),AUC为0.97。对于三种不同的诊断标准(工藤、NICE、其他),敏感性分别为86.3%、93.0%、85.0%,特异性分别为84.8%、94.4%、91.8%。
使用i-Scan进行内镜诊断具有准确的光学诊断性能,能够区分肿瘤性息肉与非肿瘤性息肉,HSROC曲线下面积超过0.90。诊断结肠息肉的敏感性和特异性均超过90%。