Kois牙面分析仪系统与用于上颌模型上架的耳杆的比较。

Comparison of the Kois Dento-Facial Analyzer System with an earbow for mounting a maxillary cast.

作者信息

Lux Laura H, Thompson Geoffrey A, Waliszewski Kenneth J, Ziebert Gerald J

机构信息

Adjunct Clinical Assistant Professor, Postgraduate Program in Prosthodontics, Marquette University School of Dentistry, Milwaukee, Wis.

Program Director, Postgraduate Program in Prosthodontics, Marquette University School of Dentistry, Milwaukee, Wis.

出版信息

J Prosthet Dent. 2015 Sep;114(3):432-9. doi: 10.1016/j.prosdent.2015.02.022. Epub 2015 Jun 5.

Abstract

STATEMENT OF PROBLEM

The Kois Dento-Facial Analyzer System (KDFA) is used by clinicians to mount maxillary casts and evaluate and treat patients. Limited information is available for understanding whether the KDFA should be considered as an alternative to an earbow.

PURPOSE

The purpose of this study was to evaluate maxillary casts mounted using the KDFA with casts mounted using Panadent's Pana-Mount Facebow (PMF). Both articulation methods were compared against a lateral cephalometric radiograph.

MATERIAL AND METHODS

Fifteen dried human skulls were used. Lateral cephalometric radiographs and 2 maxillary impressions were made of each skull. One cast from each skull was mounted on an articulator by means of the KDFA and the other by using the PMF. A standardized photograph of each articulation was made, and the distance from the articular center to the incisal edge position and the occlusal plane angle were measured. The distance from condylar center to the incisal edge and the occlusal plane angle were measured from cephalometric radiographs. Finally, the 3-dimensional position of each articulation was determined with a Panadent CPI-III. A randomized complete block design analysis of variance (RCBD) and post hoc tests (Tukey-Kramer HSD) (α=.05) were used to evaluate the occlusal plane angle and axis-central incisor distance. A paired 2-sample t test for means (α=.05) was used to compare the X, Y, and Z distance at the right and left condyle.

RESULTS

The KDFA and PMF mounted the maxillary cast in a position that was not statistically different from the skull when comparing the occlusal plane angle (P=.165). Both the KDFA and the PMF located the maxillary central incisor edge position in a significantly different position compared with the skull (P=.001) but were not significantly different from each other. The 3-dimensional location of the maxillary casts varied at the condyles by approximately 9 to 10.3 mm.

CONCLUSION

The KDFA mounted the maxillary cast in a position that was not statistically different from the PMF when comparing the incisal edge position and the occlusal plane angle. Both the KDFA and the PMF located the maxillary incisal edge position in a significantly different position compared with the anatomic position on dried human skulls.

摘要

问题陈述

临床医生使用Kois牙颌面分析仪系统(KDFA)来上架上颌模型并评估和治疗患者。关于是否应将KDFA视为耳杆的替代方法,目前可获取的信息有限。

目的

本研究的目的是评估使用KDFA上架的上颌模型与使用Panadent公司的Pana-Mount面弓(PMF)上架的模型。将两种上架方法与头颅侧位片进行比较。

材料与方法

使用了15个干燥的人类颅骨。对每个颅骨拍摄头颅侧位片并制作两个上颌印模。每个颅骨的一个模型通过KDFA安装在咬合架上,另一个通过PMF安装。对每个安装进行标准化拍照,并测量从关节中心到切缘位置的距离以及咬合平面角。从头颅侧位片中测量髁突中心到切缘的距离和咬合平面角。最后,使用Panadent CPI-III确定每个安装的三维位置。采用随机完全区组设计方差分析(RCBD)和事后检验(Tukey-Kramer HSD)(α = 0.05)来评估咬合平面角和轴-中切牙距离。使用配对双样本t检验均值(α = 0.05)来比较左右髁突处的X、Y和Z距离。

结果

在比较咬合平面角时,KDFA和PMF将上颌模型安装在与颅骨无统计学差异的位置(P = 0.165)。与颅骨相比,KDFA和PMF确定的上颌中切牙边缘位置均有显著差异(P = 0.001),但彼此之间无显著差异。上颌模型在髁突处的三维位置相差约9至10.3毫米。

结论

在比较切缘位置和咬合平面角时,KDFA安装上颌模型的位置与PMF无统计学差异。与干燥人类颅骨上的解剖位置相比,KDFA和PMF确定的上颌切缘位置均有显著差异。