Cebe Mehmet Ata, Cebe Fatma, Cengiz Mehmet Fatih, Cetin Ali Rıza, Arpag Osman Fatih, Ozturk Bora
Abant Izzet Baysal University, Faculty of Dentistry, Department of Restorative Dentistry, Bolu, Turkey.
Akdeniz University, Food Safety and Agricultural Research Center, Antalya, Turkey.
Dent Mater. 2015 Jul;31(7):e141-9. doi: 10.1016/j.dental.2015.04.008.
The purpose of this study was to evaluate the elution of Bis-GMA, TEGDMA, HEMA, and Bis-EMA monomers from six bulk fill composite resins over four different time periods, using HPLC.
Six different composite resin materials were used in the present study: Tetric Evo Ceram Bulk Fill (Ivoclar Vivadent, Amherst, NY), X-tra Fill (VOCO, Cuxhaven, Germany), Sonic Fill (Kerr, Orange, CA, USA), Filtek Bulk Fill (3M ESPE Dental Product, St. Paul, MN), SDR (Dentsply, Konstanz, Germany), EQUIA (GC America INC, Alsip, IL). The samples (4mm thickness, 5mm diameter) were prepared and polymerized for 20s with a light emitted diode unit. After fabrication, each sample was immediately immersed in 75wt% ethanol/water solution used as extraction fluid and stored in the amber colored bottles at room temperature. Ethanol/water samples were taken (0.5mL) at predefined time intervals:10m (T1), 1h (T2), 24h (T3) and 30 days (T4). These samples were analyzed by HPLC. The obtained data were analyzed with one-way ANOVA and Tukey HSD at significance level of p<0.05.
Amount of eluted Bis-EMA and Bis-GMA from Tetric Evo Ceram Bulk Fill and amount of eluted TEGDMA and HEMA from X-tra Fill higher than others composites (p<0.05).
Residual monomers were eluted from bulk fill composite resins in all time periods and the amount of eluted monomers was increased with time.
本研究的目的是使用高效液相色谱法评估六种大块充填复合树脂在四个不同时间段内双酚A缩水甘油醚(Bis-GMA)、二甲基丙烯酸三乙二醇酯(TEGDMA)、甲基丙烯酸羟乙酯(HEMA)和双甲基丙烯酸乙二酯(Bis-EMA)单体的溶出情况。
本研究使用了六种不同的复合树脂材料:Tetric Evo Ceram Bulk Fill(义获嘉伟瓦登特公司,纽约州阿默斯特)、X-tra Fill(VOCO公司,德国库克斯港)、Sonic Fill( Kerr公司,美国加利福尼亚州奥兰治)、Filtek Bulk Fill(3M ESPE牙科产品公司,明尼苏达州圣保罗)、SDR(登士柏公司,德国康斯坦茨)、EQUIA(GC美国公司,伊利诺伊州阿尔西普)。制备样品(厚度4mm,直径5mm),并用发光二极管装置聚合20秒。制作完成后,将每个样品立即浸入用作萃取液的75wt%乙醇/水溶液中,并在室温下储存在琥珀色瓶中。在预定的时间间隔:10分钟(T1)、1小时(T2)、24小时(T3)和30天(T4)采集乙醇/水样品(0.5mL)。这些样品通过高效液相色谱法进行分析。获得的数据采用单因素方差分析和Tukey HSD检验,显著性水平为p<0.05。
Tetric Evo Ceram Bulk Fill中Bis-EMA和Bis-GMA的溶出量以及X-tra Fill中TEGDMA和HEMA的溶出量高于其他复合材料(p<0.05)。
在所有时间段内,大块充填复合树脂中均有残留单体溶出,且溶出单体的量随时间增加。